3.
Check the integrity and abrasion conditions of the brush bristle, if necessary, replace the brush.
4.
Check the abrasion condition of the polishing pad, if necessary, replace it.
TANK AND FLOAT BALL FILTER CLEANING AND TANK SEALING STRIP INSPECTION
1.
Turn off the machine.
2.
Turn the recovery tank lid (A, Figure 17) 90 degree position where it can be took off from the tank, and then
take down the float ball filter (36) from the tank.
3.
Clean the recovery tank lid (A), recovery tank (B), clean water tank(C) and the float ball filter support frame
(E). Empty the recovery tank with the drain hose (15).
4.
If necessary, follow the symbols “OPEN” and “CLOSE” as shown in Figure17 to open the bottom cover (F) of
float ball filter and then clean the float ball (D), filter support frame (E) and filter sponge (I). After cleaning, fix
the float ball (D) into the filter support frame (E) and then align the mark groove (L) of the bottom cap (F) of the
float ball filter with the mark groove (L) of the float filter support frame (E). Screw the bottom cap of the float
ball filter tight, and fix the filter sponge (I) onto the float filter support frame (E). Finally, connect it to the
sewage suction hose (M).
5.
Inspect the integrity of the tank sealing strip.
NOTE
Tank sealing strip (G) makes to produce the vacuum inside the tank when suction motor works. The
tank must be sealed can effectively absorb the water from the ground to recovery tank.
6.
Check whether the contact surface of sealing strip (G) is integrity and sealing is sufficient. If necessary, take the
sealing strip of the tank out of the groove (H) and replace it. Assembly the new sealing strip as shown in
Figure16, the joint should be back in the middle area.
7.
Close the recovery tank lid (A).