3.
Unscrew the squeegee knob (16), remove the sewage suction hose (11) to take off the squeegee.
4.
Lifting the squeegee bracket by lifting lever.
5.
Cleaning the squeegee blade and taking out the special dirt and debris on the groove of supporting structure (A)
and sewage suction hose.
6.
Assembly the squeegee in the opposite order of above steps.
SQUEEGEE BLADE CHECK AND REPLACEMENT
1.
Follow the previous paragraph to cleaning the squeegee blade. (Figure 15)
2.
Check the edge of front squeegee blade (B) and rear squeegee blade (C), they should at the same horizontal line,
otherwise adjust their height by following procedures:
-
Loosen the clip (D) to separate the rear squeegee blade (C) from the bracket (A) for the adjustment of
squeegee blade, after the adjustment, lock the clip again.
-
Loosen the screw (G) and bolt (H) of handle to adjust the front squeegee blade, after that, tighten the screw
and bolt.
3.
Check the integrity of the front and rear squeegee blade whether there is any gap or crack. If necessary, replace
it by below steps.
-
Loosen the clip (D) to separate the fastener from the bracket (A), take off the clip bar (E), then turn the rear
squeegee blade (C) upside down or replace it. Re-Install the rear blade in reverse order of uninstallation.
-
Loosen the screw (G) of handle to take down the front clip bar (F) , then replace the front squeegee blade
(B) with new one. Re-install the front squeegee blade in reverse order of taking it off. After the squeegee
blade is replaced or turned upside down, adjust the height of front and rear squeegee blades according to
procedures above.
4.
Install the squeegee and use the knob (16) to fasten it, and then connect the sewage suction hose (11) to
squeegee.
5.
If necessary, adjust squeegee balance by the squeegee adjusting knob (20).
Figure 15
BRUSH OR PAD-HOLDER CLEANING
CAUTION!
It is recommended to wear gloves when cleaning the brush or pad-holder since it may contain
sharp fragments.
1.
Take the brush/pad-holder off base on procedures in previous sections.
2.
Clean the brush/pad-holder using water and detergent.
17