5925 Heisley Road • Mentor, OH 44060-1833
Holding Cabinet
FL-2361
Rev. 4 (10/13)
Page 4 of 12
INSTALLATION INSTRUCTIONS
HC-UA-11 FOR PROPANE CYLINDER INSTALLATION:
This cabinet is not intended for use with natural gas.
It is not user-convertible to natural gas.
1 . Only use a 1 lb . standard cylinder marked “PROPANE” . A larger tank can be used with an adapter (optional
accessory part number 0904-026-K See installation FL-2362) .
2 .
The cylinder must be constructed and marked in accordance with the specifications for propane cylinders of the
U .S . Department of Transportation (DOT) or CAN/CSA B339 .
3 . The Cylinder should not be allowed to remain in a high heat area, such as a car, truck or direct sunlight .
DO NOT
store at temperatures above 120°F (49° C) and in unauthorized storage areas not intended for cylinder storage.
4 .
Hold and use the cylinder in an upright position and only use when temperatures are above 10°F (-12° C). Do not
attach near flames, pilot lights or sparks.
5 . Propane Tank Hook-up:
a . Make sure the cabinet switch is in the “OFF” position .
b . Uncap the cylinder, hold upright and insert it in the right rear compartment of the cabinet . Hand screw and
tighten the cylinder to the gas regulator .
DO NOT
over-tighten.
Check for leaks at the connection: Spray soapy water onto the connection and look for bubbles . Tighten more if
needed .
6 . Disconnect the cylinder when not in use . Replace the cylinder cap when storing .
HC-UA-11-NG FOR NATURAL GAS INSTALLATION ONLY:
1 . Installation shall be made with a connector that complies with Standards for Natural Gas Connection on
Movable Appliances ANSI/Z21.69b/CSA 6.166-2006.
Adequate means to limit the movement of the cabinet without
depending on the connector, quick connect or associated piping
must be provided by the installer.
2 .
The cabinet and its individual shutoff valve must be disconnected from the gas supply piping system during
any pressure testing of the system at pressures exceeding 1/12 psig (3 .45 kPA) . During pressure testing
of the gas supply piping system at pressures equal to or less than 1/2 psig (3 .45 kPA), the cabinet must be
isolated by closing the manual shutoff valve.
3 . Check for leaks at the connection: Spray soapy water onto the connection and look for bubbles . Tighten more if
needed .