background image

5925 Heisley Road • Mentor, OH 44060-1833

Holding Cabinet

FL-2361

Rev. 4 (10/13)

Page 5 of 12

INSTALLATION INSTRUCTIONS

FOR ELECTRIC OPERATION:

Specifications: 120 Volts, 1500 Watts, 60 Hz., 1 Ph. 

12.5 Amps, 15 Amp. Service (NEMA 5-15P)

Plug the power cord into the proper wall outlet and 

push switch to “ELECTRIC” . 
Preheat cabinet for 30 minutes .

FOR PROPANE GAS OPERATION:

Specifications: (Propane) 8,700 BTU 

Connect a propane tank (per Propane Installation 

Instructions)
Push the switch to “GAS” . Preheat cabinet for 45 

minutes .

NOTES:

 New tanks may not light on the first couple 

tries . See “Re-light Burner” instructions . 

1 lb. propane tank will provide approximately 6 hours 

of heat at 160°F.

FOR NATURAL GAS OPERATION:

Specifications: 8,700 BTU at W.C. 

Notes about using gas:

1 . GAS RESET LIGHT: 

a) Red light on control panel will come on and 

an alarm will sound if the flame is not present 

when it should be . 

b) Propane tank may be empty or a draft has blown 

out the burner flames.

c) 

To re-light the burner

: Push switch to “Off” 

and then back to “Gas” quickly .

d) Wait for up to 10 seconds and then check sight 

glass below the door to see the burner flames. 

Repeat as necessary .

Call Service

 if alarm goes off repeatedly without ignition .

DO NOT ATTEMPT 

TO LIGHT BY 

HAND.  

This cabinet has an automatic ignition system.

2 . 

The battery (needed for the gas valve and the 

temperature control) keeps charging as long as the 

cord is plugged into the outlet (or when accessory 

solar panel is added) . Check the battery indicator on 

the control panel .  

NOTE:

 The battery will provide power for approximately 

16 hours (without solar) before needing a charge; 

depending on the age and condition of the battery .

WARNING

GENERAL INSTALLATION:

1 . 

Remove all paper and packing materials from the 

inside of the cabinet and install angles into posts .

2 . 

Remove protective paper and vinyl material from 

the outside of the cabinet .

3 . 

Place the cabinet in a well-ventilated area on level 

floor or ground.

4 . 

DO NOT block the flue vent located at the upper 

rear of the cabinet .

5 . Lock the two front casters before starting up or 

plugging in the cabinet .

HOW TO INSTALL ANGLES:

1 .  Insert end tabs of the angles into the post slots 

and push down .

2 .  Note the location shown in the diagram of the 

18” x 26” pan slide and the 12” x 20” pan slide

A

DETAIL A

18” X 26” BUN PAN

12” X 20”

 STEAM TABLE PAN

Summary of Contents for HC-UA-11

Page 1: ...Fax Keep this manual for future reference OPERATING and MAINTENANCE INSTRUCTIONS Models HC UA 11 Tri Powered Series Hot Cabinets HC UA 11 WARNING IMPROPER INSTALLATION SERVICE ADJUSTMENTS ALTERATIONS...

Page 2: ...hooting Guide 8 Illustration Cabinet assembly replacement parts 9 Illustration Control panel assembly 10 Illustration Burner assembly 11 Wiring Diagram 12 SERVICE POLICY and AGENCY LIST FL 1400 TABLE...

Page 3: ...Burning Appliances and Equipment CAN CSA B149 1 10 and or local codes 4 The area around cabinet must be kept free and clear from combustible materials 5 DO NOT obstruct the flow of combustion and ven...

Page 4: ...sition b Uncap the cylinder hold upright and insert it in the right rear compartment of the cabinet Hand screw and tighten the cylinder to the gas regulator DO NOT over tighten Check for leaks at the...

Page 5: ...nd then check sight glass below the door to see the burner flames Repeat as necessary Call Service if alarm goes off repeatedly without ignition DO NOT ATTEMPT TO LIGHT BY HAND This cabinet has an aut...

Page 6: ...the solar panel in order to catch the sunlight The best possible condition for solar charging is when the sunrays hit the panel straight on at 90 angle NOTE It is recommended to keep the solar panel p...

Page 7: ...id drips and splashes HOW TO CLEAN THE UNIT Soil Cleaner Method OUTER CABINET Powder Coat WEEKLY OR AS NEEDED Mild detergent and warm water 1 Wipe with clean soft cloth 2 Rinse well 3 Dry gently CABIN...

Page 8: ...it is not on 5b Thermostat is set too low 5c Propane gas tank has expired 5d A gust of wind may have blown out the flame or prevented ignition of the gas 5e Defective electrical components NOTE The co...

Page 9: ...6 Casters w Brake 0569 281 BK 7 Wire Angles 2 per kit 0621 352 K 8 Posts 0696 169 9 Sight Glass 0574 167 18 Cord Set 0810 149 19 High Limit 400 F 0848 033 20 High Limit 0848 060 21 Flanged Inlet 0713...

Page 10: ...on nameplate when ordering parts Control Panel Assembly ITEM DESCRIPTION 120V 10 Power Switch 0808 126 11 Temperature Control 0848 075 CC 12 Battery Indicator 7037 004 13 Reset Light 0766 100 14 Timer...

Page 11: ...7037 005 30 Burner Assembly Complete 8100 001 31 Control Module 8100 001 32 Regulator Solar 7037 002 33 Gas Burner 8100 002 34 Igniter 8100 005 35 Gas Valve 8100 008 36 Regulator 8100 009 37 Pressure...

Page 12: ...MIT 300 F REAR PANEL PWR CORD 3 1 2 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 31 30 29 28 27 26 25 24 24 25 26 27 28 29 30 31 38 37 36 34 33 32 39 40 32 33 34 35 36 37 38 39 40 41 42 43 44...

Reviews: