BLAST CHILLER INTRODUCTION  

 
 

THE

 BLAST CHILLER

 is the easiest and simplest way to chill foods safely without additional labor.  All food 

service operators prepare foods in advance or chill foods at the end of a workday.  More often than not the foods 
are chilled in standard refrigeration, often creating an unsafe time and temperature environment.  In using a 

BLAST CHILLER

 food products are produced in the same manner and with the same equipment which is 

used for conventional food preparation and chilled in a 

BLAST CHILLER

.  The 

BLAST CHILLER

 

resembles a reach in refrigerator.  The 

BLAST CHILLER

 is a unit that moves cool air at a high circulation 

over the top and bottom of each pan thus ensuring a rapid even chilling time.  Almost all foods are chilled 
within 2 hours out of the danger zone 140°F to 41°F.  The time necessary to bring the internal food temperature 
to 41°F. (5°C) is affected by the food density, moisture content and the food’s ability to retain heat.  Blast 
chilled food has a shelf life of five days, including day of production and service.  Blast chilling works well 
with a wide range of menu items.  Nearly any food product that can be portioned into a standard 2-1/2” hotel 
pan can be successfully blast chilled.  These systems are used for services from 50 to 10,000 meals per day. 
 

STEPS IN THE BLAST CHILL PROCESS 

 
1. 

Prepare all food products to the point of consumption.  Within 30 minutes, portion into 2-1/2 inch deep 
half-full pan or sheet pan at a depth of no more than 2 inches and weight of no more than 8 lbs. 

 
2. 

Place pans of cooked product in the 

BLAST CHILLER

 and strategically place probe in the center of 

the pan where the internal temperature is brought down to approximately 41°F (5°C) within 90 minutes. 

 
3. 

At the completion of the “chill cycle” the pans of food product are removed and covered with either a 
film wrap or stainless steel lid and labeled. 

 
4. 

The product is stored in a refrigerator and maintained at a temperature between 33°F (1°C) and 38°F 
(3°C). 

 
5. 

The food product is rethermed just prior to the required meal service in bulk or individual portion. 

 
 

 

 

 

Summary of Contents for CCBC-12-75

Page 1: ...FL 2242 Feb 2000 BLAST CHILLERS MODEL NUMBERS CCBC 4 35 CCBC 12 75 CCBC12 UA 100 INSTALLATION OPERATION SERVICE MANUAL...

Page 2: ...TION Page 10 Unpacking and Installation Instructions SECTION 3 OPERATION Page 13 Start Up Information How to Operate Blast Chill Cycle Modes Page 14 Loading of Product Page 15 Defrosting Blast Chill P...

Page 3: ...he food s ability to retain heat Blast chilled food has a shelf life of five days including day of production and service Blast chilling works well with a wide range of menu items Nearly any food prod...

Page 4: ...ally reverts to a 38 F storage refrigerator CCBC 12 75 CCBC 12 UA 100 The CCBC 12 75 and CCBC 12 UA 100 are ideal for small to medium size food service operations which require a blast chilling capabi...

Page 5: ...tor Operational Indicator Panel with Microprocessor Blast Chill Cycle Controlled Automatically by Either a Food Probe or Digital Timer Four 4 Preset Chilling Times 30 60 90 and 240 minutes Cabinet Tem...

Page 6: ...erant SPECIFICATIONS ELECTRICAL DATA Capacity lbs 90 mins 35 lbs Voltage 208 230V 60 1 Width 28 Amperage 7 Depth 32 Feed Wires Ground 2 Open Door Depth 58 3 4 10 Ft Cord Installed NEMA 6 15P Height 34...

Page 7: ...tional Features Blast Chill Processing Refrigerator 38 F Storage Refrigerator Operational Indicator Panel with Microprocessor Blast Chill Cycle Controlled Automatically by Either Food Probes or Digita...

Page 8: ...of Automatically Large Surface Area Evaporator and High Velocity Fan Contained in a Separate Service Compartment Automatic Defrost CFC Free R 134A Refrigerant SPECIFICATIONS ELECTRICAL DATA Capacity...

Page 9: ...Blast Chiller Standard Features Stainless Steel Exterior and Interior Two Operational Features Blast Chill Processing Refrigerator 38 F Storage Refrigerator Operational Indicator Panel with Microproc...

Page 10: ...eavy Duty Swivel Casters with Locking Brakes on the Front Automatic Defrost Condensation Disposed of Automatically Large Surface Area Evaporator and High Velocity Fan Contained in a Separate Compartme...

Page 11: ...t programming over Control Panel For CCBC 12 75 CCBC 12 UA 100 1 Select Chill Mode 2 Select Hard or Soft Blast 3 Select Timer for probe or time of process 4 When satisfied with selections press Check...

Page 12: ...cedure WARNING DO NOT Under any Circumstances Lay Your New Equipment Down on Either The Back Front or Sides 1 Check for any instructions printed on shipping carton 2 Remove protective cardboard corner...

Page 13: ...receptacle is available at the installation location Model CCBC12 UA 100 requires a qualified electrician to furnish and install wiring for the power supply This must be connected to the identified t...

Page 14: ...l power source for correct voltage phase and ampacity Refer to cabinet data plate for requirements 8 Remove electrical control box cover and check all wiring connections for a secure hold On rare occa...

Page 15: ...LAST CHILLER left standby button Display panel will indicate cabinet temperature 3 There may be an indicator A7 This indicates that there has been a power failure 4 Press the red x cancel button to ca...

Page 16: ...g The blast chiller converts to a standard refrigerator During the defrost operation the temperature in the chiller will not exceed 3 C 38 F and it is therefore safe to leave products in the chiller d...

Page 17: ...eats all products should not be more than 2 in depth 1 1 2 is recommended for very dense items such a lasagna and beef stew 3 There should not be more than 7 lbs of product per shelf 4 Roast meats sho...

Page 18: ...cycle some fans will stop running This is normal When the defrost cycle is finished the compressor will run for approximately 90 seconds before the fans operate Following every defrost period there i...

Page 19: ...ff button Main Power Failure Ticket If the main power fails for more than five 5 seconds a ticket is automatically printed which gives the time of power failure and the time at which power is stored S...

Page 20: ...c pads for cleaning and scouring 4 Rinse thoroughly with fresh water after every Cleaning operation 5 Always wipe dry to avoid watermarks SOIL CLEANER METHOD Routine Cleaning Soap ammonia or detergent...

Page 21: ...PARAMETER SET AT bss Blast Soft Stat 33 bhs Blast Hard Stat 12 bfs Blast Freeze Stat 16 sss Store Soft Stat 33 shs Store Hard Stat 33 sfs Store Freeze Stat 8 bsd Blast Soft Differential 35 bhd Blast H...

Page 22: ...ing store see table below but will still show the probe temperature during blast 7 Seg Display Alarm Condition a0 AIR ON SENSOR FAILURE a1 WALL SENSOR FAILURE a2 FIN SENSOR FAILURE a3 FOOD PROBE 1 FAI...

Page 23: ...display shows OFF Turn cabinet on by pressing OFF ON button 1 Compressor not running a Manually close compressor contactor if utilized temporarily to see if compressor runs b If compressor runs check...

Page 24: ...sulator 5 Container too large distance from outside of container to center of food within is too great shouldn t exceed 2 inches for optimum performance 6 Container material is plastic an insulator in...

Page 25: ...of thermocouple wire is reversed Evaporator won t run 1 Breaker not on if equipped 2 Motor overload tripped if equipped 3 In post defrost Drip period 4 Fan door switch is open if equipped 5 Blown fus...

Page 26: ...ept closed Remove before restarting Alarm conditions 1 Cabinet wall temperature above 38 F more than 60 minutes 2 Defrost termination on time instead of temperature 3 Compressor overheating if tempera...

Page 27: ...Section 6 Parts and Drawings ______________________ __ Page 24 Parts List and Breakdown Drawing of Blast Chillers...

Page 28: ...Page 25...

Page 29: ...80MM X 430MM WGASKET 905 13 HINGE PLATE R7 OPAL TOP WHINGE 020 14 HINGE SPRING LOADED WHINGE 290 15 STANDARD DOOR WWBC35 STD DOOR 99 1 16 EVAPORATOR 4X13X17 WEVAP 485 17 DRIP TRAY WDT WBC35 99 1 18 DE...

Page 30: ...Page 27...

Page 31: ...DOOR NYLON WDOOR NYLON NEW 17 HINGE SPRING LOADED WHINGE 290 18 SWITCH THERMAL HEATED 331 528 WSWITCH 200 19 CASTOR 6 W BRAKE WCASTOR 040 19a CASTOR 6 NO BRAKE WCASTOR 030 20 HINGE PLATE R4 OPAL T2U...

Page 32: ...Page 29...

Page 33: ...NYLON WDOOR NYLON NEW 17 HINGE SPRING LOADED WHINGE 290 18 SWITCH THERMAL HEATED WSWITCH 200 19 CASTOR 6 W BRAKE WCASTOR 040 19a CASTOR 6 NO BRAKE WCASTOR 030 20 HINGE PLATE R4 OPAL T2U WHINGE 070 21...

Page 34: ...the pull down time C Food thickness the greater the distance from geometric core center of food to its surface the longer the pull down time D Food density the greater the density the longer the pull...

Page 35: ...ax 800 378 8333 E mail to parts service crescor com Or Mail To CresCor 5925 Heisley Road Mentor OH 44060 Toll Free 877 273 7267 Fax 440 350 7267 See us online at http www crescor com Questions Call an...

Page 36: ...________________________________ __________________________________________________________ __________________________________________________________ _________________________________________________...

Page 37: ...guidelines Recommended doneness for rethermalization is 155 F 68 C Do not overcook Proportioned Meats hamburger patty pork chop Salisbury steak etc Cook according to recipe If sauce or gravy is requir...

Page 38: ...rkey beef and vegetable sauce separately from the crust pastry or biscuit Top product after chilling or at point of rethermalization Stir Frys Saut steam until meat is done and vegetables are crisp Pa...

Page 39: ...Vegetables Frozen vegetables do not require cooking before rethermalization For bulk rethermalization vegetables do not need to be cooked or blast chilled before service and should be prepared as in...

Page 40: ...potatoes well drained can be used without further cooking Mashed Potato flakes or powder Follow recipe according to the package Product should be smooth easy to scoop and hold its form loosely at the...

Page 41: ...o prepare further than one day ahead to avoid excess moisture Use meat items with little or no bone to get a drier product Fried foods should be produced conventionally when possible CEREALS Cooked ce...

Page 42: ...wrap and immediately blast chill Omelets Frozen convenience product must be fully tempered prior to assembly For omelets prepared conventionally follow existing standardized recipe Omelet should be sl...

Page 43: ...AKFAST SANDWICHES Prepare sandwich filling separately and chill Assemble sandwiches wrap and blast chill for additional 15 20 minutes HASH BROWNS OVEN FRIES For both convenience and freshness prepare...

Reviews: