SERVICE & TROUBLESHOOTING
Setting or Resetting Time and Date
SET UP PROCEDURE
SWITCH
FUNCTION IN SPECIAL SWITCH MODE
I/O
ON/OFF SWITCH
1
When held in, displays the code for current parameter
2
Step back to previous parameter, and while held in displays the parameter
code. When released, displays the value of the parameter.
3
Advance to the next parameter. (same as above)
Increase the value of the current parameter.
X
Decrease the value of the current parameter
To set the parameters complete the following steps:
1. This can
only
be entered from the panel
OFF
mode.
2. Press and
HOLD IN
any key
EXCEPT
the
ON/OFF
key for three seconds.
3.
While Holding key
, press and release the
ON/OFF
key.
You will now be in the programming mode.
CODE
PARAMETER
SET AT:
bss
Blast Soft Stat
33
bhs
Blast Hard Stat
12
bfs
Blast Freeze Stat
-16
sss
Store Soft Stat
33
shs
Store Hard Stat
33
sfs
Store Freeze Stat
-8
bsd
Blast Soft Differential
35
bhd
Blast Hard Differential
35
bfd
Blast Freeze Differtial
35
ssd
Store Soft Differential
35
sfd
Store Freeze Differential
35
bd1
Blast Duration 1 (normally 30 min.)
30
bd2
Blast Duration 2 (normally 60 min.)
60
bd3
Blast Duration 3 (normally 90 min.)
90
bd4
Blast Duration 4 (normally 240 min)
240
cab
Cabinet Number
1
ala
Alarm Duration
900 (15 min)
ddc
Defrost Duration for Cabinet
Hex. Switch
dic
Defrost Interval for Cabinet
Hex. Switch
ddp
N/A defrost Duration for PoD minutes, Set Manually
dip
N/A defrost Interval Hours, Set Manually
det
Defrost Target Temperature
39
yr
Calander Year Setting
Set Accordingly
nth
Calander Month Setting
Set Accordingly
day
Calander Day Setting
Set Accordingly
hr
Calander Hour Setting
Set Accordingly
ute
Calander Minute Setting
Set Accordingly