background image

Cir

cuit Diagram - TSRE Series A

INDICA

TES WHITE WIRE

INDICA

TES BLACK WIRE

LOWER LEFT ST

AT

(130° BLUE)

LOWER

RIGHT ST

AT

(130° BLUE)

ROOM 

THERMISTER

FITTED  TO MAIN 

CONTROLLER 

MODULE 

BOOST LIMIT

ST

AT (120° GREEN)

MANUAL CUTOUT

 

(140°)

USER INTERF

ACE

EAR

TH

EAR

TH

EAR

TH

NEUTRAL (PEAK)

LIVE (PEAK)

LIVE (OFF-PEAK)

NEUTRAL (OFF-PEAK)

FA

N

PCB

LIMIT ST

AT

(125° BLACK)

CORE THERMISTER

MOUNTED TO INNER SIDE  (o/w PLASTIC HOUSING)

STORAGE ELEMENTS

34

Summary of Contents for TSRE050

Page 1: ...Operating These instructions should be read carefully and retained for future use Note also the information presented on the appliance Creda TSRE Storage Heater Models TSRE050 TSRE070 TSRE100 TSRE125...

Page 2: ...ater Once the heater has cooled down it will reset automatically it will continue to cycle on and off automatically until the reason for overheating is removed The display screen may flash red to indi...

Page 3: ...ulations The peak supply must be connected via a switched fused spur with a fuse rated suitably for the appliances flex the off peak supply via a 20A double pole switch Failure to follow these instruc...

Page 4: ...e if they have been given supervision or instruction concerning use of the appliance Children shall not play with the appliance Cleaning and user maintenance shall not be made by children without supe...

Page 5: ...l RAL7035 anodised Battery Backup 3 3V coin cell battery to backup real time clock Battery life 5 years Supply each 1 N PE 230 240V 50Hz Peak Off Peak Class II IP Rating IPX4 Approvals CE BEAB Warrant...

Page 6: ...removing the packaging CAUTION SHOULD BE TAKEN NOT TO REST THE HEATER UPON THE ROOM TEMPERATURE SENSOR HOUSING Fig 1b Dispose of packaging in an appropriate way Read these instructions carefully befor...

Page 7: ...r and 150mm min 75mm either side Ensure the back of the heater is flush against the wall If the skirting board is taller than 120mm and deeper than 15mm it should be cut to accommodate safe installati...

Page 8: ...rpeted then the carpet should be slit and underlay cut away to allow the feet to rest firmly on the floor Carpet gripper must be locally removed so that the feet may rest in a level position This appl...

Page 9: ...have been fitted Move the heater away from the wall drill the holes and fit the wall fixings best suited to the application Secure the heater to the wall using correct quantity of screws required per...

Page 10: ...Not suitable for use on single supply Storage Fan circuit Fan Circuit PEAK L Storage Circuit OFF PEAK L Fan Circuit PEAK N Storage Circuit OFF PEAK N The earth wire should be connected into the earth...

Page 11: ...for connection Fig 8 IMPORTANT Only heat resistant ordinary polyvinyl chloride sheathed flexible cord should be used the following codes apply IEC 60227 IEC57 or CENELEC H05V2V2 F Maximum Cable Sizes...

Page 12: ...Fig 9 Fig 10 Fig 11 Fig 12 12...

Page 13: ...grooves facing upwards and fitting neatly around the element Angle the element upward to fit the energy cell Position the second energy cell in the row against the left hand insulation Place the rema...

Page 14: ...U Fig 13 Fig 14 Fig 15 Fig 16 14...

Page 15: ...inner front panel complete with insulation starting at position U and working clockwise Fig 16 Ensure the bottom tabs are located inside the chassis and that the screws are tightly secured down each e...

Page 16: ...enu Button 3 Back Button 4 Up and Down Arrows 5 Enter Button 6 Advance Button 7 Heating Status NOTE Should the heater fail to operate this may be due to the room temperature being higher than the ther...

Page 17: ...ges based on the temperature selected showing deep blue through to bright red 5 Enter is used within the menu options to confirm settings On the main screen pressing Enter will display the enabled fea...

Page 18: ...has a battery backup that will keep the clock running in the event of a mains power outage To adjust the time or date follow the steps below Press the Menu button Select Date Time by pressing the Ente...

Page 19: ...ble throughout the day and these can be customised for each day of the week Factory default times 06 30 until 09 30 11 00 until 13 00 15 00 until 17 00 18 00 until 22 00 2 Out All Day pre programmed h...

Page 20: ...t the end of each period select Next to move to the following period When a day is complete select Save to update it Once the first day has been set up it is possible to copy these settings to success...

Page 21: ...to choose a temperature to be maintained during this period and press the Enter button At the end of the holiday mode the heater will automatically revert back to the previously selected programme Tim...

Page 22: ...heat is not required press the Advance button and the heater will turn off until the beginning of the next Comfort On period Boost mode provides temporary heating for one two or three hours Auto Boost...

Page 23: ...le or disable Wireless Connectivity If additional RF Module is connected user will have option to enable or disable RF communications In cases where unauthorised persons may tamper with the control se...

Page 24: ...able to deliver the required comfort level then it is possible to force the heater to store additional energy In this way more electrical energy is stored during the off peak period and this will inc...

Page 25: ...Service personnel use only If more than one heater is installed in the same room it is recommended that the smallest capacity heater is set as a Slave Disabled as factory default Rm Temp Offset for S...

Page 26: ...pacity heater is set as the master and all smaller capacity products are set as slaves Press Menu Back and Enter for 3 seconds to enter the service menu select Slave Mode and press Enter Select Enable...

Page 27: ...This page is deliberately left blank 27...

Page 28: ...heat escaping through the windows 5 Windows Nearly 25 of heat loss can occur through poorly insulated frames and single glazing If you can t afford to double glaze all your windows go for the rooms yo...

Page 29: ...can sometimes occur immediately above a heater due to the properties of some paints and decorating materials or the presence of environmental impurities in the air such as soot cigarette smoke or ince...

Page 30: ...e Helpline on 0344 879 35 88 or visit http www credaheating co uk contact and complete the online form For ROI please email serviceireland glendimplex com or call 353 0 1 842 833 We will need details...

Page 31: ...l receipt as proof of purchase and if required by Creda proof of delivery If you are unable to provide this documentation you will be required to pay for any repair work required Any repair work under...

Page 32: ...17 Set the cover and the screw safely to one side 2 Slide the catch and pull the module up from the User Interface as shown in Fig 18 3 Move the module clear of the User Interface to access the batter...

Page 33: ...imer Yes Model Identifier s TSRE050 TSRE070 TSRE100 TSRE125 TSRE150 Unit Heat output Nominal heat output Pnom 0 5 0 75 1 0 1 25 1 5 kW Minimum heat output indicative Pmin 0 0 0 0 0 0 0 0 0 0 kW Maximu...

Page 34: ...GHT STAT 130 BLUE ROOM THERMISTER FITTED TO MAIN CONTROLLER MODULE BOOST LIMIT STAT 120 GREEN MANUAL CUTOUT 140 USER INTERFACE EARTH EARTH EARTH NEUTRAL PEAK LIVE PEAK LIVE OFF PEAK NEUTRAL OFF PEAK F...

Page 35: ...35...

Page 36: ...ntial requirements of EEC Directives 2006 95 EC and 2004 108 EC Customer Helpline 0344 879 35 88 aftersales credaheating co uk www credaheating co uk Glen Dimplex Heating Ventilation Millbrook House G...

Reviews: