![Creda TSRE050 Instruction Manual Download Page 8](http://html1.mh-extra.com/html/creda/tsre050/tsre050_instruction-manual_2682133008.webp)
The heater must be securely fixed to a wall. Screws with suitable wall fixings for solid walls
are provided. If other wall types are encountered it is the installer who must choose the most
suitable fixing.
SUGGESTED FIXINGS
SOLID BRICK/BLOCK: No. 10 size high temperature resistant plastic inserts, 8mm drill bit. Drill
hole 15mm deeper than plastic insert length.
PLASTERBOARD - If possible locate studding and use No. 10 woodscrews directly into the
wood, otherwise M5 rawlplug intersets are suitable.
NOTE: FOR OTHER WALL TYPES (eg. timber frame and hollow concrete) SEEK SPECIALIST
ADVICE.
If the floor is carpeted then the carpet should be slit and underlay cut away to allow the feet
to rest firmly on the floor. Carpet gripper must be locally removed so that the feet may rest in
a level position.
This appliance is heavy. The floor must be checked to ensure that it is capable of bearing the
weight of the unit, up to 165kg.
This Heater is rated IPX4
DO NOT UNDER ANY CIRCUMSTANCES ATTEMPT TO MOVE OR REPOSITION
THIS HEATER WITHOUT SEEKING EXPERT ADVICE. THE HEATER SHOULD
NEVER BE FREED FROM THE WALL WITH ENERGY CELLS INSIDE.
USE CAUTION WHEN INSTALLING THIS PRODUCT, UNPAINTED METALWORK
CAN HAVE SHARP EDGES.
IMPORTANT
Head of wall fixing screw must be flanged pan head type and have a diameter
no less than 11mm. No countersunk headed screws to be used for wall fixing.
Fig. 5
Fig. 4
Installing the Heater
8
Summary of Contents for TSRE050
Page 12: ...Fig 9 Fig 10 Fig 11 Fig 12 12...
Page 14: ...U Fig 13 Fig 14 Fig 15 Fig 16 14...
Page 27: ...This page is deliberately left blank 27...
Page 35: ...35...