PLEASE DON’T TAKE CHANCES

Site conditions may vary considerably and Creda cannot recommend 

the  correct  wall  fixings  to  be  used.    It  is  the  responsibility  of  the 

installer to ensure that adequate permanent fixing has been achieved.  

Purely for guidance the suggested fixings are made for certain wall 

materials but this list is not comprehensive or authoritative.  Different 

wall  constructions  will  need  different  inserts.    Note  that  inserts 

incorporating plastic may be subject to shrinkage behind a warm 

storage heater and are therefore not recommended.

Wall fixings can be obtained from local stockists

CARPETS:

 For safety, the heater must be positioned in the room so that there at least 75mm (3”) free air space 

all around it; under windows, ensure that curtains, when drawn, cannot touch or cover the heater casing.  In 

order to maintain stability, it is essential that the heater be placed on a level surface and care should be taken 

to avoid irregular surfaces, such as may result from carpets or tiled surrounds partially protruding under the 

heater.  The heater feet are designed to go underneath a carpet rather than standing on it; this permits the 

weight to be taken on a firm base and makes for neatness and ease of cleaning with vacuum cleaners, etc. 

underneath the heater.  Carpet gripper should be removed from behind the heater feet. 

BRICKS: 

The heater casing and the heater storage bricks with which it must be fitted, are delivered in separate 

packages.  The brick is common to all heaters, packed in pairs.
The brick catalogue number is 791402015.  7934 models have 8 bricks.  7935 models have 12 bricks.  
7936 have 16 bricks.

WALL FIXING:

 The heater must ALWAYS be mounted against, and fixed to a wall as it will not stand up by 

itself.  A detachable bracket is provided for screwing to the wall, the heater is then placed in position and fixed 
to the bracket by a screw at each end.  The heater must never be unscrewed or moved from the wall bracket 
whilst it is loaded with bricks.  THE HEATER IS VERY HEAVY AND WILL BE DANGEROUS IF ITS WALL FIXING 
BECOMES INSECURE.

Solid Brick and Concrete 
Walls

No. 10 Rawlplug plastic inserts. 
Drill hole of 8mm dia to a depth 
of 15mm greater than depth of the 
insert.

Panelled Wall, Paramount Board, Chipboard, Plaster-
board, etc.

Check that the panel itself is adequately fixed to battens etc.  Use 
Rawlplug M5 intersets; drill accurate 10mm dia holes in single skin 
plasterboard.  One fixing should be in studwork.

Hollow concrete, Breeze Block and Thermolite Block 
Walls

RAWLPLUG ‘RAWLOK R6054R’.  Some authorities suggest UNIFIX 
LB 70/10mm.  

Timber Frame

Seek specialist advice, some 
authorities suggest RAWLNUT

Summary of Contents for Newera TSR12AW

Page 1: ...ds EN60335 2 30 and the European Standard Electromagnetic Compatibility EMC EN55014 EN60555 2 and EN60555 3 These cover the essential requirements of EEC Directives 2006 95 EC and 2004 108 EC GDC Grou...

Page 2: ...avoid overheating do not cover the surfaces of the heater Do not put clothes fabrics or any other materials on the heaters Do not place objects in contact with the heater Do not position the heater w...

Page 3: ...of cleaning with vacuum cleaners etc underneath the heater Carpet gripper should be removed from behind the heater feet BRICKS The heater casing and the heater storage bricks with which it must be fit...

Page 4: ...on floor proper lay carpet over foot slitting it as shown it is unnecessary to cut carpet away Stand the heater against the wall in its intended position Mark the position of the two outside corners...

Page 5: ...ontact with the casing A shelf unit is separately available for fitting above heaters 4 When bracket is securely fixed replace the heater under the bracket angle and align screw holes on heaters ends...

Page 6: ...WITCHED ON ENSURE THAT ALL PACKAGING MATERIAL IS REMOVED FROM THE BRICKS BEFORE FITTING THEM MAINS TERMINALS IMPORTANT for earthing loosen the earth screw sufficiently to wrap the mains earth wire aro...

Page 7: ...front panel Temporarily remove one central element to provide access for the rear rank of bricks Loosen terminals on one of the elements and remove this to allow installation of rear rank of storage...

Page 8: ...NS WITH THE FLAT ON THE KNOB BOSS 12 13 SETTING THE CONTROLS The controls are located under the lockable flap at the right hand corner of the top panel To adjust the controls on the heater use a coin...

Reviews: