Creda Newera TSR12AW Assembly Instruction Manual Download Page 8

Check that the front insulation slab is properly attached to the inner 
front  panel  and  refit  panel  (insulation  innermost)    to  the  heater  by 
locating  its  bottom  edge  behind  the  front  lip  of  the  chassis,  and 
inserting retaining screws along the top and both sides. With the bricks 

pushed well back, as mentioned earlier, and the insulation properly aligned, there should 
be no bulging of this panel and no undue force necessary to fix it.
Refit the front / top assembly by hooking the rear edge of the top panel over the rear edge of the casing, then swing the  
front panel carefully down against the casing. Replace the screws along the rear of the top and the base of the front 
panel which had been removed in Step 5.  ENSURE WALL BRACKET SCREWS ARE TIGHTENED FULLY. 
WARNING.  When  a  new  heater  is  run  up  to  temperature,  the  materials  will  produce  a  smell  for  the  first  few  days, 
these are normally harmless in a well ventilated room. It is best to make these first overnight charges with the ‘Charge 
Controller/Auto-Set’ knob at ‘Maximum’.  Caged birds, young children and people with chest ailments are best kept 
out of the room for this first period.
WET BRICKS: If accidentally, the bricks have become wet due to their having been left out-of-doors, some moisture may 
be driven off during the first overnight charging and this may drip on to the floor. If there is any doubt on this score, 
advise the customer to lay newspaper beneath the heater to protect carpets etc.   REFIT THE CONTROL KNOBS: PLEASE 
OBSERVE THE FLAT ON THE ‘D’ SHAPED SPINDLE ALIGNS WITH THE FLAT ON THE KNOB BOSS.

12

13

SETTING THE CONTROLS

The  controls  are  located  under  the  lockable  flap  at 

the right hand corner of the top panel.  To adjust the 

controls on the heater use a coin and engage it in the 

slot provided on the top surface of the knob.

AUTOMATIC CHARGING DEVICE (AUTO-SET Fitted only on Sensor Plus) 

The Auto-Set Control rations the 

overnight charge each night by sensing the room temperature. 

The knob is marked with the numbers 1 to 6, turning the knob to a lower number will reduce the charge consequently, 

the level of room warmth the next day.

Once set, the knob should need no further adjustment and the Auto-Set will maintain automatically the room warmth 

each day by varying the charge according to the weather.

1.  Set the room temperature (output) control knob to setting 4.

2.  Turn the Auto-Set Knob clockwise as far as it will go.

3.  Leave the heater to run in this condition for two nights in order to quickly disperse the ’new’ smell which is better 

removed once and for all.

4.  Instruct the user to set the Auto-Set down to his chosen setting on the third day.

 

Instructions on this are given in the Users Guide which we ask you to ensure is left with the user.

MANUALLY ADJUSTED HEATER (without Auto-Set Control)

On this the user sets the overnight charge on the numbered knob marked ‘Input’.

Setting up procedure;

1.  Turn the ‘lnput’ knob to maximum setting (6)

2.  Set the ‘Output’ knob to setting No. 4.

3.  Leave the heater to run in this condition for two nights in order to quickly disperse the new smell.

4.  Instruct the user to set the ‘Input’ to his chosen setting on the third day. Instructions on this are given in the Users 

Guide which we ask you to ensure is left with the user.

 Part No. 84299 

Iss. No. 12

Summary of Contents for Newera TSR12AW

Page 1: ...ds EN60335 2 30 and the European Standard Electromagnetic Compatibility EMC EN55014 EN60555 2 and EN60555 3 These cover the essential requirements of EEC Directives 2006 95 EC and 2004 108 EC GDC Grou...

Page 2: ...avoid overheating do not cover the surfaces of the heater Do not put clothes fabrics or any other materials on the heaters Do not place objects in contact with the heater Do not position the heater w...

Page 3: ...of cleaning with vacuum cleaners etc underneath the heater Carpet gripper should be removed from behind the heater feet BRICKS The heater casing and the heater storage bricks with which it must be fit...

Page 4: ...on floor proper lay carpet over foot slitting it as shown it is unnecessary to cut carpet away Stand the heater against the wall in its intended position Mark the position of the two outside corners...

Page 5: ...ontact with the casing A shelf unit is separately available for fitting above heaters 4 When bracket is securely fixed replace the heater under the bracket angle and align screw holes on heaters ends...

Page 6: ...WITCHED ON ENSURE THAT ALL PACKAGING MATERIAL IS REMOVED FROM THE BRICKS BEFORE FITTING THEM MAINS TERMINALS IMPORTANT for earthing loosen the earth screw sufficiently to wrap the mains earth wire aro...

Page 7: ...front panel Temporarily remove one central element to provide access for the rear rank of bricks Loosen terminals on one of the elements and remove this to allow installation of rear rank of storage...

Page 8: ...NS WITH THE FLAT ON THE KNOB BOSS 12 13 SETTING THE CONTROLS The controls are located under the lockable flap at the right hand corner of the top panel To adjust the controls on the heater use a coin...

Reviews: