2、Product dimensions
• To keep the heating wire clean, because the service life of the heating wire
will be shorten due to pollution. And Teflon paint cloth should be wiped clean
with a damp cloth constantly.
• The package may be damaged with long vacuum time. So correct vacuum
time should be set according to the package property.
• When packing the liquid, it should ensure that there is no leakage in the
process of packaging, or it may lead to damage of the vacuum pump.
-2-
English
■ 1.4 Maintenance
• Only the people who know or are familiar with the performance of the equipment
or professional maintenance personnel may conduct the maintenance.
• It should be ensured that the equipment is still and its power is cut off with
cover down when maintained.
• Only the original accessories can be used when maintained. Some standard parts
are allowed (e.g. screws, etc.).
• It is forbidden to use acid, alkali or other corrosive solutions to wipe the vacuum
cover glass surface and vacuum chamber fuselage.
• It is forbidden to use sharp hard objects to scrape or knock on the glass surface
of vacuum cover.
type
VP 160
VP 180
Voltage
220V/50HZ
Power
0.25KW
Gas extraction rate
4m³/h
≧
-0.09Mpa
Vacuum oil
-5-10
℃
- ISOVG 32 10-40
℃
-ISOVG 100
Net weight
≈
20KG
≈
24KG
Vacuum chamber size
305X300X110mm
355X300X110mm
Vacuum chamber volume
≈
7L
≈
9L
Sealing dimension
260X6mm
310X6mm
Spacer dimension
260X180X20mm
310X180X20mm
Overall dimension
360X490X210mm
410X490X210mm