77
National Rejectors, Inc. GmbH, Buxtehude
c
2
Configuration
b
aTch
confiGuraTion
Storing desired configuration in HENRI
First of all connect the HENRI setting module to the coin changer with the
configuration to be cloned (see section "Connecting HENRI" in Chap. 2
"General information").
Quick approach:
= HENRI main menu >
= Extended functions >
= Clone >
= c
2
->HENRI
Press key ...
How often?
effect
1
1 x
You enter the HENRI main menu
2
1 x
You enter submenu
e
xTenDeD
funcTions
3
1 x
You want the configuration of the coin
changer connected to be saved for
batch configuration in HENRI
4
1 x
Data is being transferred to HENRI.
Following the 100% display message:
5
1 x
You enter submenu
c
lone
again
Transferring desired configuration to coin changers
First of all connect the HENRI setting module to the coin changer to be
configured with the clone (see section "Connecting HENRI" in Chap. 2
"General information").
Quick approach:
= HENRI main menu >
= Extended functions >
= Clone >
= HENRI->c
2
Press key ...
How often?
effect
1
1 x
You enter the HENRI main menu
2
1 x
You enter submenu
e
xTenDeD
funcTions
3
1 x
You want the c
2
configuration stored
in HENRI to be transferred to the coin
changer connected
4
1 x
The stored configuration file(s) is/are
displayed
5
1 x
Data is being transferred to the coin
changer. Following the 100% display
message:
6
1 x
You enter submenu
c
lone
again
7
2 x
You enter the HENR main menu again
8
1 x/2 x
You return to the c
2
operating mode/c
2
main menu
Please repeat cloning for all coin changers to be configured.