9
CHART ‘D’
MODEL NO
.
SIZE
IMP
. DIA.
INCHES
(MM)
HP
V
O
LT
PH
HZ
RPM
NEMA ST
AR
T
CODE
FULL LOA
D
AMPS
SER
VICE
FA
CT
OR
SER
VICE
FA
CT
OR
AMPS
LOCKED R
O
TO
R
AMPS
DRIVER FRAME
CORD P/N
▲
CORD SIZE
CORD O.
D
.
WINDING
RESIST
ANCE
7366N-617-65-32N
6MH
12.80 (325)
50
460
3
60
1750
F
67.1
1.2
79.0
339.0
4
138318
6/4 - 18/4
1.14 ± .03
.15
7366N-617-80-32N
6MH
12.80 (325)
50
575
3
60
1750
F
53.7
1.2
63.2
271.2
4
138318
6/4 - 18/4
1.14 ± .03
.245
7366N-617-66-32N
6MH
13.58 (345)
60
460
3
60
1750
E
79.0
1.2
95.5
339.0
4
138319
2/4 - 18/4
1.47 ± .03
.15
7366N-617-81-32N
6MH
13.58 (345)
60
575
3
60
1750
E
63.2
1.2
76.4
271.2
4
138318
6/4 - 18/4
1.14 ± .03
.245
7366N-621-31-32N
6MH
13.58 (345)
20
208
3
60
1150
H
60.3
1.2
71.5
354.0
4
138318
6/4 - 18/4
1.14 ± .03
.111
7
230
57.2
1.2
69.8
4
138318
6/4 - 18/4
7366N-621-32-32N
6MH
13.98 (355)
25
208
3
60
1150
G
75.2
1.2
90.8
354.0
4
138319
2/4 - 18/4
1.47 ± .03
.15
230
70.8
1.2
82.6
7366N-621-92-32N
6MH
13.98 (355)
25
460
3
60
1150
G
35.4
1.2
41.3
177.0
4
138317
8/4 - 18/4
1.12 ± .02
.4397
7366N-621-1B-32N
6MH
13.98 (355)
25
575
3
60
1150
G
28.3
1.2
33.0
141.6
4
138317
8/4 - 18/4
1.12 ± .02
.6857
7366N-621-33-32N
6MH
14.57 (370)
30
208
3
60
1150
E
90.8
1.2
114.9
354.0
4
138319
2/4 - 18/4
1.47 ± .03
.111
7
230
82.6
1.2
99.7
4
138319
2/4 - 18/4
7366N-621-93-32N
6MH
14.57 (370)
30
460
3
60
1150
E
41.3
1.2
49.9
177.0
4
138317
8/4 - 18/4
1.12 ± .02
.4397
7366N-621-1C-32N
6MH
14.57 (370)
30
575
3
60
1150
E
33.0
1.2
39.9
141.6
4
138317
8/4 - 18/4
1.12 ± .02
.6857
7366N-663-16-32N
6DL
8.47 (215)
20
208
3
60
1750
G
63.0
1.2
74.6
323.0
4
138318
6/4 - 18/4
1.47 ± .03
.098
7366N-663-32-32N
6DL
8.66 (220)
25
208
3
60
1750
G
77.8
1.2
93.4
359.0
4
138319
2/4 - 18/4
1.47 ± .03
.098
230
71.4
1.2
82.3
4
138319
2/4 - 18/4
7366N-663-33-32N
6DL
8.86 (225)
30
208
3
60
1750
E
93.4
1.2
116.9
359.0
4
138319
2/4 - 18/4
1.47 ± .03
0.098
230
82.3
1.2
98.7
4
138319
2/4 - 18/4
▲
CORD SOLD SEP
ARA
TEL
Y.
IMPOR
TANT !
1.)
MOISTURE
AND
TEMPERA
TURE
SENSORS
MUST
BE CONNECTED
TO V
ALIDA
TE
THE CSA
LISTING.
2.)
A SPECIAL
MOISTURE SENSOR RELA
Y IS REQUIRED IN
THE CONTROL
P
ANEL
FOR PROPER OPERA
TION OF
THE MOISTURE SENSORS.CONT
ACT
CP&S FOR INFORMA
TION
CONCERNING MOISTURE SENSING RELA
YS FOR CUST
OMER SUPPLIED CONTROL
P
ANELS.
3.)
THESE PUMPS
ARE CSA
LISTED FOR PUMPING W
ATER
AND W
ASTEW
ATER.
DO NOT USE T
O PUMP
FLAMMABLE LIQUIDS
. NOT
SUIT
ABLE FOR ENVIRONMENTS
CONT
AINING GASOLINE OR HEXANE.
4.)
INST
ALLA
TIONS SUCH
AS DECORA
TIVE FOUNT
AINS OR W
ATER FEA
TURES PROVIDED FOR VISUAL
ENJOYMENT
MUST
BE INST
ALLED IN
ACCORDANCE WITH
THE
NA
TIONAL
ELECTRIC CODE
ANSI/NFP
A 70
AND/OR
THE
AUTHORITY
HA
VING JURISDICTION.
THIS PUMP
IS NOT
INTENDED FOR USE IN SWIMMING POOLS, RECREA
TIONAL
W
ATER P
ARKS, OR INST
ALLA
TIONS IN WHICH HUMAN CONT
ACT
WITH PUMPED MEDIA
IS
A COMMON OCCURRENCE.
5.)
WINDING RESIST
ANCE ± 7.5%. WINDING RESIST
ANCE MEASURED IN OHMS @ 25°C (BETWEEN LINES)
AT
MOT
OR LEADS.
6.)
PUMP
RA
TED FOR OPERA
TION
AT
± 10% VOL
TAGE
AT
MOT
OR.
7.)
CORD SUFFIX: XF - 50 FEET
, XJ - 75 FEET
, OR XL
- 100 FEET
. CORD SOLD SEP
ARA
TEL
Y.
Summary of Contents for DEMING 7366N-411-16-32N
Page 23: ...23 FIGURE 9 Cross Section ...
Page 24: ...24 Exploded View FIGURE 10 ...
Page 51: ...51 Notes ...
Page 52: ...52 Notes ...