12
CHART ‘G’
MODEL NO
.
SIZE
IMP
. DIA.
INCHES
(MM)
HP
V
O
LT
PH
HZ
RPM
NEMA ST
AR
T
CODE
FULL LOA
D
AMPS
SER
VICE
FA
CT
OR
SER
VICE
FA
CT
OR
AMPS
LOCKED R
O
TO
R
AMPS
DRIVER FRAME
CORD P/N
▲
CORD SIZE
CORD O.
D
.
WINDING
RESIST
ANCE
7366N-850-66-32N
8T
9.84 (250)
60.0
460
3
60
1750
E
79.0
1.2
95.5
339.0
4
138319
2/4 - 18/4
1.47 ± .03
.15
7366N-850-81-32N
8T
9.84 (250)
60.0
575
3
60
1750
E
63.2
1.2
76.4
271.2
4
138318
6/4 - 18/4
1.14 ± .03
.245
7366N-823-31-32N
8T
**
20.0
208
3
60
1150
H
60.3
1.2
71.5
354.0
4
138318
6/4 - 18/4
1.14 ± .03
.3277
230
57.2
69.8
7366N-823-32-32N
8T
10.24 (260)
25.0
208
3
60
1150
G
75.2
1.2
90.8
354.0
4
138319
2/4 - 18/4
1.47 ± .03
.111
7
230
70.8
1.2
82.6
7366N-823-92-32N
8T
10.24 (260)
25.0
460
3
60
1150
G
35.4
1.2
41.3
177.0
4
138317
8/4 - 18/4
1.12 ± .02
.4397
7366N-823-1B-32N
8T
10.24 (260)
25.0
575
3
60
1150
G
28.3
1.2
33.0
141.6
4
138317
8/4 - 18/4
1.12 ± .02
.6857
7366N-823-33-32N
8T
10.63 (270)
30.0
208
3
60
1150
E
90.8
1.2
114.9
354.0
4
138319
2/4 - 18/4
1.47 ± .03
.111
7
230
82.6
1.2
99.7
7366N-823-93-32N
8T
10.63 (270)
30.0
460
3
60
1150
E
41.3
1.2
49.9
177.0
4
138317
8/4 - 18/4
1.12 ± .02
.4397
7366N-823-1C-32N
8T
10.63 (270)
30.0
575
3
60
1150
E
33.0
1.2
39.9
141.6
4
138317
8/4 - 18/4
1.12 ± .02
.6857
7366N-823-49-32N
8T
11.61 (295)
40.0
230
3
60
1150
E
110.4
1.2
131.8
476.0
4
138319
2/4 - 18/4
1.47 ± .03
.0819
7366N-823-64-32N
8T
11.61 (295)
40.0
460
3
60
1150
E
55.2
1.2
65.9
238.0
4
138318
6/4 - 18/4
1.14 ± .03
.3277
7366N-823-79-32N
8T
11.61 (295)
40.0
575
3
60
1150
E
44.2
1.2
52.7
190.4
4
138317
8/4 - 18/4
1.12 ± .02
.5443
▲
CORD SOLD SEP
ARA
TEL
Y.
IMPOR
TANT !
1.)
MOISTURE
AND
TEMPERA
TURE
SENSORS
MUST
BE CONNECTED
TO V
ALIDA
TE
THE CSA
LISTING.
2.)
A SPECIAL
MOISTURE SENSOR RELA
Y IS REQUIRED IN
THE CONTROL
P
ANEL
FOR PROPER OPERA
TION OF
THE MOISTURE SENSORS.CONT
ACT
CP&S FOR INFORMA
TION
CONCERNING MOISTURE SENSING RELA
YS FOR CUST
OMER SUPPLIED CONTROL
P
ANELS.
3.)
THESE PUMPS
ARE CSA
LISTED FOR PUMPING W
ATER
AND W
ASTEW
ATER.
DO NOT USE T
O PUMP
FLAMMABLE LIQUIDS
. NOT
SUIT
ABLE FOR ENVIRONMENTS
CONT
AINING GASOLINE OR HEXANE.
4.)
INST
ALLA
TIONS SUCH
AS DECORA
TIVE FOUNT
AINS OR W
ATER FEA
TURES PROVIDED FOR VISUAL
ENJOYMENT
MUST
BE INST
ALLED IN
ACCORDANCE WITH
THE
NA
TIONAL
ELECTRIC CODE
ANSI/NFP
A 70
AND/OR
THE
AUTHORITY
HA
VING JURISDICTION.
THIS PUMP
IS NOT
INTENDED FOR USE IN SWIMMING POOLS, RECREA
TIONAL
W
ATER P
ARKS, OR INST
ALLA
TIONS IN WHICH HUMAN CONT
ACT
WITH PUMPED MEDIA
IS
A COMMON OCCURRENCE.
5.)
WINDING RESIST
ANCE ± 7.5%. WINDING RESIST
ANCE MEASURED IN OHMS @ 25°C (BETWEEN LINES)
AT
MOT
OR LEADS.
6.)
PUMP
RA
TED FOR OPERA
TION
AT
± 10% VOL
TAGE
AT
MOT
OR.
7.)
CORD SUFFIX: XF - 50 FEET
, XJ - 75 FEET
, OR XL
- 100 FEET
. CORD SOLD SEP
ARA
TEL
Y.