COMPRESSOR WILL NOT START
Compressor will not start.
Service door open.
Close service
door.
Compressor is
unplugged.
Plug
compressor in
outlet on face of
AC distribution
box.
Defective door interlock
switch.
Replace
Low voltage.
Check power
source.
Defective thermostat.
Replace.
Defective starting
component (capacitor,
relay).
Replace.
Defective compressor.
Replace.
Troubleshooting Tip:
Use a short 15 Amp extension cord and
plug the compressor directly into the wall outlet.
This will bypass the AC distribution box.
Note: For Testing Purposes Only.