47
These charts are intended as a guide to isolate and correct most problems you might encounter. Should your
machine show ‘OUT OF SERVICE”, go in the TEST MODE and press “B” to list errors.
ALL COINS ARE REJECTED
All coins are rejected.
Main Power OFF /
Disconnected.
Apply power
Blown Fuse
Check fuses and
replace if
necessary.
Loose connection.
Check cable at
coin mech and
controller board.
Jammed coin
mechanism.
Clear coins.
Weak springs on changer
gate. (COINCO units
only.)
Replace spring.
Gate partially open.
Clean and reset
gate. If
COINCO unit,
check spring.
Dirty / faulty coin sensor.
Clean / Replace.
Incompatible coin
mechanism.
Replace.
Defective coin
mechanism.
Replace.
Defective controller
board.
Replace.