10
MODEL
NO
PA
R
T
NO
HP
V
O
LT
PH
Hz
RPM (Nom)
NEMA ST
AR
T
CODE
FULL LOA
D
AMPS
SER
VICE
FA
CT
OR
LOCKED R
O
TO
R
AMPS
CORD P/N
▲
CORD SIZE
CORD O.
D
.
WINDING
RESIST
ANCE
MAIN - ST
AR
T
XGVHH Pump - Horiz.
XGVHH75N2
143385
7.5
208
3
60
3450
M
28.0
1.0
173.9
125496
12/4 - 18/4
.86 ± .02
0.40
230
28.2
201.0
460
14.1
100.5
125497
12/4 - 18/4
.86 ± .02
1.58
XGVHH7552
143386
7.5
575
3
60
3450
M
11.3
1.0
80.4
125497
12/4 - 18/4
.86 ± .02
2.47
XGVHH100N2
143387
10.0
208
3
60
3450
K
37.0
1.0
173.9
125498
8/4 - 18/4
1.12 ± .02
0.40
230
34.8
201.0
460
17.4
100.5
125497
12/4 - 18/4
.86 ± .02
1.58
XGVHH10052
143388
10.0
575
3
60
3450
K
13.9
1.0
80.4
125497
12/4 - 18/4
.86 ± .02
2.47
NOTE:
A
3” Pipe Spool Kit is recommended for use of a XGVHH with a 3x3 BAF
.
IMPOR
TANT !
Moisture and
Temperature sensor leads are integral to power cord.
Pump rated for operation at ± 10% voltage at motor
.
▲
Cord Suffix: XC - 30 Feet, XF - 50 Feet, XJ - 75 Feet, or XL
- 100 Feet
.
▲ Cord sold separately
.
Single Phase pumpes require start components to be included in panel. Provided with pump.