background image

7 - ENG

A14083

HOW TO PREVENT IT

WHAT CAN HAPPEN

WARNING: Risk of Burns

Touching exposed metal such as the 
compressor head or outlet tubes, can 
result in serious burns.

Never touch any exposed metal parts 
on compressor 
during or immediately 
after operation. Compressor will remain 
hot 
for several minutes after operation.
Do not reach around protective shrouds 
or attempt maintenance until unit has 
been allowed to cool.

HOW TO PREVENT IT

WHAT CAN HAPPEN

WARNING: Risk from Moving Parts

Never operate the compressor with 
guards 
or covers which are damaged or 
removed.

Moving parts such as the pulley, flywheel, 
and belt can cause serious injury if 
they come into contact with you or your 
clothing.

HAZARD

HAZARD

Any repairs required on this product 
should be performed by authorized 
service center personnel.

Attempting to operate compressor with 
damaged or missing parts
 or attempting 
to repair compressor with protective 
shrouds removed can expose you to 
moving parts and can result in serious 
injury.

WARNING: Risk of Falling

A portable compressor can fall from 
a table, workbench, or roof causing 
damage to the compressor and could 
result in serious injury or death to the 
operator.

Always operate compressor in a stable 
secure position
 to prevent accidental 
movement of the unit. Never operate 
compressor on a roof or other elevated 
position. Use additional air hose to 
reach high locations.

HAZARD

How To Prevent It

What Could Happen

Summary of Contents for 919.724123

Page 1: ...fety Guidelines Assembly Operation Maintenance Service and Adjustments Troubleshooting Repair Parts Model No 919 724123 CAUTION Read the Safety Guidelines and All Instructions Carefully Before Operating Sold by Sears Canada Inc Toronto Ont M5B 2B8 A14083 Rev 0 11 19 05 ...

Page 2: ...m the date of purchase This Craftsman Air Compressor warranty gives you specific legal rights and you may have other rights which vary from province to province Sears Canada Inc Toronto Ont M5B 2B8 TABLE OF CONTENTS WARRANTY 2 SPECIFICATION CHART 3 SAFETY GUIDELINES 3 8 GLOSSARY 9 ACCESSORIES 9 DUTY CYCLE 9 ASSEMBLY 10 INSTALLATION 11 12 OPERATION 13 15 MAINTENANCE 16 SERVICE AND ADJUSTMENTS 17 18...

Page 3: ...ate of California to cause cancer birth defects or other reproductive harm Some example of these chemicals are lead from lead based paints crystalline silica from bricks and cement and other masonry products arsenic and chromium from chemically treated lumber Your risk from these exposures varies depending on how often you do this type of work To reduce your exposure to these chemicals work in a w...

Page 4: ...property damage To reduce the risk of fire do not allow the compressor to operate unattended Always operate the compressor in a well ventilated area free of combustible materials gasoline or solvent vapors If spraying flammable materials locate compressor at least 20 feet away from spray area An additional length of hose may be required Store flammable materials in a secure location away from comp...

Page 5: ...sor 1 Failure to properly drain condensed water from tank causing rust and thinning of the steel tank 2 Modifications or attempted repairs to the tank 3 Unauthorized modifications to the unloader valve safety valve or any other components which control tank pressure Never drill into weld or make any modifications to the tank or its attachments 4 Excessive vibration can weaken the air tank and caus...

Page 6: ...h the compressor is connected provides proper electrical grounding correct voltage and adequate fuse protection The compressed air directly from your compressor is not safe for breathing The air stream may contain carbon monoxide toxic vapors or solid particles from the tank Breathing these contaminants can cause serious injury or death Sprayed materials such as paint paint solvents paint remover ...

Page 7: ...can cause serious injury if they come into contact with you or your clothing HAZARD HAZARD Any repairs required on this product should be performed by authorized service center personnel Attempting to operate compressor with damaged or missing parts or attempting to repair compressor with protective shrouds removed can expose you to moving parts and can result in serious injury WARNING Risk of Fal...

Page 8: ...h a fire extinguisher Do not operate machine with missing broken or unauthorized parts Unsafe operation of your air compressor could lead to serious injury or death to you or others HAZARD HOW TO PREVENT IT WHAT CAN HAPPEN WARNING Risk or Serious Injury or Property Damage When Transporting Compressor Oil can leak or spill and could result in fire or breathing hazard serious injury or death can res...

Page 9: ...run air pressure in the air tank begins to build It builds to a certain high pressure before the motor automatically shuts off protecting your air tank from pressure higher than its capacity The high pressure at which the motor shuts off is called cut out pressure Branch Circuit Circuit carrying electricity from electrical panel to outlet This unit is capable of powering the following Accessories ...

Page 10: ...lean and dry underside of air tank leg opposite wheels Remove the protective strip from the adhesive backed molded foot bumpers Attach the foot bumpers to the bottom of leg on each end Press firmly into place Installing Handles Wheels and Molded Foot Bumpers The wheels and handle do not provide adequate clearance stability or support for pulling the unit up and down stairs or steps The unit must b...

Page 11: ...of a short circuit grounding reduces the risk of shock by providing an escape wire for the electric current This air compressor must be properly grounded The portable air compressor is equipped with a cord having a grounding wire with an appropriate grounding plug see following illustrations The plug must be used with an outlet that has been installed and grounded in accordance with all local code...

Page 12: ...ltage and minimum branch circuit requirements Certain air compressors can be operated on a 15 amp circuit if the following conditions are met 1 Voltage supply through branch circuit is 15 amps 2 Circuit is not used to supply any other electrical needs lights appliances etc 3 Extension cords comply with specifications 4 Circuit is equipped with a 15 amp circuit breaker or 15 amp time delay fuse NOT...

Page 13: ...miliar with these controls before operating the unit On Auto Off Switch Turn this switch ON AUTO to provide automatic power to the pressure switch and OFF to remove power at the end of each use Pressure Switch The pressure switch automatically starts the motor when the air tank pressure drops below the factory set cut in pressure It stops the motor when the air tank pressure reaches the factory se...

Page 14: ... result if the following break in instructions are not closely followed This procedure is required before the air compressor is put into service and when the check valve or a complete compressor pump has been replaced 1 Make sure the On Auto Off lever is in the OFF position NOTE Pull coupler back until it clicks to prevent air from escaping through the quick connect 2 Plug the power cord into the ...

Page 15: ...ble vapors If the compressor is being used to operate a sprayer DO NOT place near the spray area Before Each Start Up 1 Set On Auto Off lever to OFF and close air regulator 2 Pull regulator knob out turn counter clockwise until it stops Push knob in to lock in place 3 Attach hose and accessories NOTE The hose or accessory will require a quick connect plug if the air outlet is equipped with a quick...

Page 16: ... that the safety valve operates freely If the valve is stuck or does not operate smoothly it must be replaced with the same type of valve To Drain Tank 1 Set the On Auto Off lever to OFF 2 Pull the regulator knob out and turn counter clockwise to set the outlet pressure to zero 3 Remove the air tool or accessory 4 Pull ring on safety valve allowing air to bleed from the tank until tank pressure is...

Page 17: ...SERVICE AND ADJUSTMENTS Unit cycles automatically when power is on When doing Maintenance you may be exposed to voltage sources compressed air or moving parts Personal injuries can occur Before performing any Maintenance or repair unplug the compressor and bleed off all air pressure ALL MAINTENANCE AND REPAIR OPERATIONS NOT LISTED MUST BE PERFORMED BY TRAINED SERVICE TECHNICIAN In closed position ...

Page 18: ...om damage such as being stepped on or run over Wind them loosely around the compressor handle If so equipped Store the air compressor in a clean and dry location 5 Using an adjustable wrench or 5 8 wrench remove the regulator manifold 6 Apply pipe sealant to new regulator manifold and assemble tighten with wrench 7 Reapply pipe sealant to gauges quick connect and safety valve 8 Reassemble all comp...

Page 19: ...ssure safety valve pops off Tube fittings are not tight enough Tighten fittings where air can be heard escaping Check fittings with soapy water solution Do Not Overtighten Air leaks at fittings Air leaks in air tank or at air tank welds Defective air tank Air tank must be replaced Do not repair the leak Do not drill into weld or otherwise modify air tank or it will weaken The tank can rupture or e...

Page 20: ... accessory is being used Compressor is not supplying enough air to operate accessories Prolonged excessive use of air Compressor is not large enough for air requirement Hole in hose Check valve restricted Air leaks Decrease amount of air usage Check the accessory air requirement If it is higher than the SCFM or pressure supplied by your air compressor you need a larger compressor Check and replace...

Page 21: ...Check for proper fuse You should use a time delay fuse Check for low voltage problem Check the extension cord Disconnect the other electrical appliances from circuit or operate the compressor on its own branch circuit Have checked by a Trained Service Technician Fuse blown circuit breaker tripped Extension cord is wrong length or gauge Loose electrical connections Faulty motor Check the extension ...

Page 22: ...utilisé à des fins commerciales ou comme appareil de location Cette garantie sur le compresseur d air de Craftsman vous donne des droits particuliers Il se peut que vous ayez d autres droits qui varient d une province à l autre Sears Canada Inc Toronto Ont M5B 2B8 GARANTIE 26 TABLEAU DES SPÉCIFICATIONS 27 MESURES DE SÉCURITÉ DÉFINITIONS 27 MESURES DE SÉCURITÉ IMPORTANTES 27 32 LEXIQUE 33 ACCESSOIR...

Page 23: ... à ces produits chimiques travaillez dans un endroit bien aéré et utilisez de l équipement de sécurité approuvé portez toujours un masque facial ou respirateur homologué MSHA NIOSH bien ajusté lorsque vous utilisez de tels outils Lorsque vous utilisez un outil pneumatique il faut toujours suivre les mesures de sécurité de base afin de réduire le risque de blessures corporelles MESURES DE SÉCURITÉ ...

Page 24: ...er le compresseur à une distance d au moins 20 pieds 6 m de la zone de vaporisation Il peut s avérer nécessaire d utiliser un boyau supplémentaire Entreposer les matières inflammables dans un endroit sécuritaire loin du compresseur Ne jamais placer des objets contre ou sur le compresseur Utiliser le compresseur dans un endroit ouvert à au moins 12 pouces 30 cm de tout mur ou obstruction qui réduit...

Page 25: ...qui risque de causer des dommages à la propriété ou des blessures Porter toujours des lunettes de protection homologuées ANSI Z87 1 avec des écrans latéraux lors de l utilisation du compresseur Ne jamais diriger la buse ou le vaporisateur vers soi vers d autres personnes ou vers des animaux Toujours mettre le compresseur hors fonction et purger la pression du boyau d air et du réservoir avant d en...

Page 26: ...es de mise à la terre L air obtenu directement du compresseur ne devrait jamais être utilisé comme source d air pour les être humains Si l air produit par ce compresseur sera utilisé pour la respiration il faut installer des filtres appropriés ainsi que du matériel de sécurité Les filtres en ligne et le matériel de sécurité utilisés avec le compresseur doivent être dans la mesure de traiter l air ...

Page 27: ... après vente autorisé Les pièces mobiles telles que la poulie le volant moteur et la courroie peuvent entraîner des blessures graves si elles entrent en contact avec une partie du corps ou des vêtements En tentant de faire fonctionner le compresseur avec des pièces manquantes ou endommagées ou de réparer le compresseur sans les gardes de protection on s expose aux pièces mobiles ce qui peut entraî...

Page 28: ...ez jamais d annuler les caractéristiques de sécurité de ce produit Assurez vous qu un extincteur d incendie est disponible dans l aire de travail N utilisez pas l appareil avec des pièces brisées manquantes ou non autorisées AVERTISSEMENT Risque de dommages à la propriété pendant le transport du compresseur Des fuites ou des déversements d huile peuvent se produire et entraîner des risques d incen...

Page 29: ...d air dans le réservoir commence à s accumuler La pression monte et atteint un niveau élevé réglé à l usine avant que le moteur ne s arrête automatiquement protégeant ainsi le réservoir d air d un taux de pression qui excèderait sa capacité La haute pression à laquelle le moteur s arrête s appelle la pression de rupture Circuit de dérivation Le circuit acheminant l électricité du tableau électriqu...

Page 30: ...té opposé des roues Enlevez la bande protectrice de la surface adhésive des pare chocs moulés pour pieds Attachez un pare chocs sur la surface inférieure de chaque jambe Pressez les fermement en place Installation des poignées des roues et des pare chocs moulés pour pieds Les roues et la poignée n offrent pas assez de dégagement de stabilité ou de support pour tirer l appareil en ascendant ou en d...

Page 31: ... un cordon muni d un fil de mise à la terre et d une fiche appropriée de mise à la terre voir l illustration ci dessous La fiche doit être insérée dans une prise de courant installée et mise à la terre conformément à tous les codes et ordonnances électriques locaux 1 Le cordon fourni avec cet appareil comprend une fiche avec broche de mise à la terre La fiche DOIT être insérée dans une prise de co...

Page 32: ...on contre la surtension et protection du circuit Consulter le tableau des spécifications pour connaître les exigences minimums concernant la tension et le circuit de dérivation Certains modèles de compresseur d air peuvent fonctionner sur un circuit de 15 ampères si les conditions suivantes sont satisfaites 1 la tension d alimentation au circuit de dérivation est de 15 A 2 le circuit n est pas uti...

Page 33: ...liser l appareil Interrupteur marche automatique arrêt On Auto Off Placez cet interrupteur à la position ON AUTO pour alimenter le manostat et à la position OFF pour couper le courant après chaque utilisation Manostat Le manostat démarre automatiquement le moteur lorsque la pression dans le réservoir d air tombe à une valeur inférieure à la pression d amorçage réglée à l usine Il arrête le moteur ...

Page 34: ...ète du compresseur Cette procédure doit être exécutée avant d utiliser le compresseur d air pour la première fois et après le remplacement de la soupape de retenue ou de la pompe complète du compresseur 1 Assurez vous que le levier marche automatique arrêt On Auto Off est en position d arrêt OFF REMARQUE Tirez le raccord vers l arrière jusqu à ce qu il s enclenche afin d empêcher la fuite d air du...

Page 35: ... Si le compresseur est utilisé avec un vaporisateur NE PAS placer le compresseur près de la région de vaporisation Avant chaque mise en marche 1 Placez le levier On Auto Off à la position OFF 2 Tirez le bouton du régulateur et tournez le dans le sens contraire des aiguilles d une montre jusqu à ce qu il s arrête Poussez le bouton pour le verrouiller 3 Raccordez le boyau et les accessoires REMARQUE...

Page 36: ...e que la pression dans le réservoir se situe à environ 20 lb po2 Relâchez l anneau de la soupape de sûreté 5 Vidangez l eau du réservoir en ouvrant le robinet de vidange Tournez dans le sens contraire des aiguilles d une montre situé en bas du réservoir L eau dans le réservoir d air peut condenser Si l eau n est pas vidangée cela risque de corroder et d affaiblir le réservoir d air produisant ains...

Page 37: ... section sur l utilisation ENTRETIEN ET RÉGLAGES Le compresseur d air fonctionne automatiquement lorsqu il est sous tension En effectuant l entretien vous pourriez être exposé aux sources de tension à de l air comprimé ou aux pièces en mouvement et subir ainsi des blessures corporelles Avant de procéder à tout entretien ou réparation débranchez le compresseur et purgez tout l air pressurisé TOUS L...

Page 38: ...les sans contrainte autour de la poignée du compresseur d air le cas échéant Rangez le compresseur d air dans un endroit propre et sec 5 À l aide d une clé à molette ou d une clé de 5 8 po 16 mm retirez le collecteur du régulateur 6 Appliquez un produit d étanchéité pour tuyaux au collecteur de régulateur neuf et montez le Serrez le collecteur avec une clé 7 Appliquez un produit d étanchéité pour ...

Page 39: ...ntendre l air s échapper Vérifiez les raccords à l aide d une solution d eau savonneuse Ne Pas Trop Serrer Fuites d air aux raccords Fuites d air à la soupape de décharge du manostat Soupape de décharge défectueuse du manostat Contactez un technicien qualifié Fuites d air au réservoir d air ou aux soudures du réservoir Réservoir d air défectueux Le réservoir d air doit être remplacé Ne tentez pas ...

Page 40: ...aire fonctionner les accessoires Utilisation prolongée et excessive de l air Le compresseur n est pas assez gros pour la quantité d air requise Trou dans le boyau Soupape de retenue obstruée Fuites d air Diminuez la quantité d air utilisé Vérifiez les exigences en air de l accessoire Si elles sont plus élevées que la valeur SCFM pi3 min ou la pression produite par le compresseur vous avez besoin d...

Page 41: ...s utiliser un fusible ou un coupe circuit à valeur nominale supérieure à la valeur spécifiée pour le circuit de dérivation utilisé Vérifier si le fusible est du type approprié Vous devriez utiliser un fusible retardé Vérifier s il y a une condition de tension basse Vérifiez la rallonge Déconnectez tout autre appareil électrique du circuit ou branchez le compresseur sur son propre circuit de dériva...

Page 42: ...50 FR A14083 REMARQUE ...

Page 43: ...51 FR A14083 REMARQUE ...

Page 44: ...com Your Home For repair in your home of all major brand appliances lawn and garden equipment or heating and cooling systems no matter who made it no matter who sold it For the replacement parts accessories and owner s manuals that you need to do it yourself For Sears professional installation of home appliances and items like garage door openers and water heaters 1 800 4 MY HOME Anytime day or ni...