background image

2

EN

USER MANUAL

CRAFTSMAN

®

 STUD SENSOR

The stud sensor uses electronic signals to locate the edges of studs or joists through 
drywall and plywood up to 3/4”. Once the edge of a stud has been detected, the stud 
sensor displays a red LED and sounds an audible tone. A pencil notch allows you to 
easily note the stud edge on the wall.

WARNING

Protect Your Eyes. Wear Safety Goggles

OPERATING INSTRUCTIONS

BATTERY: 

Open door on back of unit and connect a 9-volt battery to clip. Put battery back into 
case and close back battery door.

USAGE:
Fig. 1

 - Hold the stud sensor flat against the surface, making 

firm contact.
• Press in and hold the activation button. The green and red 
LED’s will light. When the red LED goes off, the unit is calibrated. 
Keep holding the activation button during all of the following 
procedures. 

Note:

 While calibrating, the stud sensor must not be placed 

directly over a stud, dense material such as metal, or over a wet 
or newly painted area, or it will not properly calibrate. If the Red 
LED stays lit, move to a different location and try again.

Fig. 2

 - Slide the stud sensor slowly across the surface in a 

straight line. As it detects a stud edge, the red LED will go on and 
an audible tone will be heard. 
• Use the handy pencil notch located at the top of the unit to 
mark the stud edge.

Fig. 3-4

 - Repeat the above steps from the other side of the stud. 

Coming from the opposite direction, mark the other edge of the 
stud. The midpoint of the two marks indicates the stud center.

CAUTIONS ON OPERATING

The proximity of electrical wiring or pipes to the surface of the 
wall may cause the stud sensor to detect them as studs. You 
should always use caution when nailing, cutting or drilling in 
walls, ceilings and floors that may contain these items. Always 
remember that studs or joists are normally spaced 16 inches or 
24 inches apart and are 1-1/2 inches in width. To avoid surprises 
be aware that anything closer together or of a different width may 
not be a stud. 

Power LED

Activation 

Button

Marking Notch

Edge 
Detection LED

Fig. 1

Fig. 2

Fig. 3

Fig. 4

Summary of Contents for 77-075

Page 1: ...Stud Sensor Sensor De Parales Capteur De Poteaux Sensor de vigas 77 075 ...

Page 2: ...a wet or newly painted area or it will not properly calibrate If the Red LED stays lit move to a different location and try again Fig 2 Slide the stud sensor slowly across the surface in a straight line As it detects a stud edge the red LED will go on and an audible tone will be heard Use the handy pencil notch located at the top of the unit to mark the stud edge Fig 3 4 Repeat the above steps fro...

Page 3: ...elative humidity Depth Range Accuracy Scanning and marking the stud from two sides Up to 19 mm through drywall Stud center 1 8 3 mm for wood 1 4 6 mm for metal Shock Resistance Up to 3 feet 1 m dropped onto concrete Water Resistance Water resistant but not waterproof Operating Temperature 20 F to 120 F 7 C to 49 C Storage Temperature 20 F to 150 F 29 C to 66 C LIMITED WARRANTY Duration of coverage...

Page 4: ...s procedimientos siguientes Nota Mientras se calibra el Sensor de Parales no deberá ser colocado directamente sobre un paral materiales densos como el metal o sobre una área mojada o con pintura de lo contrario no calibrará apropiadamente Si la luz LED reja se queda pre ndida muévalo a otra ubicación y trate de nuevo Fig 2 Deslice lentamente el Sensor de Parales sobre la superficie en línea recta ...

Page 5: ...ión descrita anteriormente también con el pedazo de cartón en posición También es particularmente importante en este tipo de uso recordarse de mantener su mano libre alejada de la unidad ESPECIFICACIONES De 35 a 55 de humedad relativa Rango de Profundidad Hasta Precisión Escaneo y marcado del paral desde ambos lados 19 mm por entre una pared de yeso Centro del paral 1 8 3 mm para madera o 1 4 6 mm...

Page 6: ... le détecteur de montant ne doit pas être placé directement sur un montant du matériau dense comme le métal une surface mouillée ou fraîchement peinte ou il sera mal étalonné Si la diode rouge ne s éteint pas déplacez le et essayez de nouveau Fig 2 Glissez le détecteur de montant doucement sur la surface selon une ligne droite À mesure qu il détecte un bord de montant la diode rouge s allume et un...

Page 7: ...ment important dans ce cas de vous souvenir de garder votre main libre à l écart de l unité FICHE TECHNIQUE Entre 35 et 55 d humidité relative Plage de profondeur Précision En balayant et marquant des deux côtés du montant Jusqu à 19 mm po à travers les murs de plâtre Centre du montant 3 mm 1 8 po pour le bois ou 6 mm 1 4 po pour le métal Résistance aux chocs Chute de pas plus de 1 m 3 pi sur le b...

Page 8: ...8 Notes ...

Page 9: ... 2018 CRAFTSMAN 701 EAST JOPPA ROAD TOWSON MARYLAND 21286 WWW CRAFTSMAN COM 022674 MARCH 2018 ...

Page 10: ...ucentredugoujon 2 3 4 WEARSAFETYGOGGLES USEGAFASPROTECTORAS PORTERDESLUNETTESDESÉCURITÉ UTILIZEÓCULOSDEPROTEÇÃO REQUIRESA9VOLTBATTERY NOTINCLUDED REQUIREUNABATERIADE9VOLTIOS NOESINCLUIDA FONCTIONNEAVECPILEDE9VOLTS NONINCLUSE REQUEREUMABATERIADE9VOLTS NÃOINCLUSO WARNING ADVERTENCIA AVERTISSEMENT ATENÇÃO WWW CRAFTSMAN COM 2018STANLEYTOOLS 701E JOPPAROAD TOWSON MARYLAND 21286 U S CANADAONLY É U ETCAN...

Reviews: