To prevent possible SERIOUS INJURY or DEATH from
electrocution:
• Be sure power is not connected BEFORE installing door
control.
• Connect ONLY to 24 VOLT low voltage wires.
To prevent possible SERIOUS INJURY or DEATH from a closing
garage door:
• Install door control within sight of garage door, out of reach
of children at a minimum height of 5' (1.5 m), and away from
all moving parts of door.
• NEVER permit children to operate or play with door control
push buttons or remote control transmitters.
• Activate door ONLY when it can be seen clearly, is properly
adjusted, and there are no obstructions to door travel.
• ALWAYS keep garage door in sight until completely closed.
NEVER permit anyone to cross path of closing garage door.
Drywall Anchors
Insulated
Staples
Screw 6ABx1-1/4"
Control Panel (std installation)
Screw 6-32x1"
Control Panel (pre-wired)
HARDWARE SHOWN ACTUAL SIZE
Outside Keylock Accessory Connections
To opener quick-connect terminals: white to white;
white/red to red.
To Replace,
Insert Top
Tabs First
To Remove,
Twist
Here
PRE-WIRED
INSTALLATION
REMO
V
E & REPLACE CO
V
ER
LOCK
LIGHT
Figure 1
Figure 2
24
V
olt
2-Conductor
Bell Wire
INSTALLATION STEP 7
Install the Door Control
Locate door control within sight of door, at a minimum
height of 5 feet (1.52 m) where small children cannot
reach, away from moving parts of door and door
hardware. If installing into drywall, drill 5/32" holes and use
the anchors provided. For pre-wired installations (as in
new home construction), it may be mounted to a single
gang box (Figure 2).
1. Strip 7/16" (11 mm) of insulation from one end of bell
wire and connect to the two screw terminals on back of
door control by color: white wire to 2 and white/red wire
to the 1.
2. Remove cover by gently prying at slot in side of the
cover with a small flat head screwdriver. Fasten with
6ABx1-1/4" self-tapping screws (drywall installation) or
6-32x1" machine screws (into gang box) as follows:
• Drill and install bottom screw, allowing 1/8" (3 mm) to
protrude above wall surface.
• Position bottom of door control on screw head and
slide down to secure. Adjust screw for snug fit.
• Drill and install top screw with care to avoid cracking
plastic housing.
Do not over tighten.
• Insert top tabs and snap on cover.
3.
(Standard installation only)
Run bell wire up wall and
across ceiling to motor unit. Use insulated staples to
secure wire in several places. Do not pierce wire with a
staple, creating a short or open circuit. If your access
door is near the garage door, you may run this wire with
the Safety Reversing Sensor wires along the top of the
rail. See page 17.
4. Insert all wires through the opening on top of motor unit
above the terminal block on the back panel (Figure 3).
5. Strip 7/16" (11 mm) of insulation from each set of wires.
Insert door control wire into quick-connect terminals by
color: white wire to white, white/red wire to red.
Separate white and white/black wires sufficiently to
connect to the opener quick-connect terminals. Twist
like colored wires together. Insert wires into
quick-connect holes: white to white and white/black to
grey.
NOTE:
When connecting multiple door controls to the
opener, twist same color wires together. Insert wires into
quick-connect holes: white to white and red/white to red.
6. Use tacks or staples to permanently attach entrapment
warning label to wall near door control, and manual
release/safety reverse test label in a prominent location
on inside of garage door.
NOTE:
DO NOT connect the power and operate the
opener at this time. The trolley will travel to the full
open position but will not return to the close position
until the sensor beam is connected and properly
aligned.
To insert or release
w
ire, p
u
sh
in ta
b
w
ith scre
w
dri
v
er tip
Door Control
Connections
Red
Grey
W
hite
To Door Control
To Sensors
Q
u
ick-
Connect Terminal
Lock
Light
Lighted
Push
Button
LOCK
LIG
HT
Terminal
Screws
Top
Mounting Hole
Bottom
Mounting Hole
PREMIUM
CONTROL
CONSOLE
BACK
V
IEW
WHITE
2
RED
1
Figure 3
Strip 7/16" (11 mm) of insulation from each wire.
Insert wires through opening on top of motor
unit above terminal block, then into
quick-connect terminals.