page 6
6. Wiring.
7. Canopy Assembly.
Remove 2 screws on underside of hanging bracket.
Lift canopy to hanging bracket. Align holes in
canopy with holes in hanging bracket. While holding
canopy in place, slide anti-sway adapter up to
canopy. Align holes in anti-sway adapter with holes
in bottom of canopy and then re-insert the screws
that were previously removed. Tighten both screws
securely.
Slide canopy cover up to anti-sway adapter, aligning
rounded part of slotted holes in canopy cover with
screw heads in bottom of anti-sway adapter. Turn
canopy cover to the right (clockwise) until it stops.
This fan is remote control adaptable (remote control
sold separately).
Note
: Only remote controls approved
for DAMP locations can be used with this fan.
WARNING
: Turn off circuit breakers to current fixture
from breaker panel and be sure switch is turned to the
OFF position.
CAUTION
:
Be sure outlet box is properly grounded and that
a ground wire (
GREEN
or Bare) is present.
Make sure all electrical connections comply with Local
Codes or Ordinances and the National Electrical Code. If you
are unfamiliar with electrical wiring or if the house/building
wires are different colors than those referred to below,
please use a qualified electrician.
Note:
Excess lead wire length from the fan can be cut to the
desired length and then stripped.
When downrod is secured in place on the hanging
bracket, electrical wiring can be made as follows:
Connect
BLACK
wire from fan to
BLACK
wire from
ceiling with wire connector provided.
Connect
WHITE
wire from fan to
WHITE
wire from
ceiling with wire connector provided.
Connect all
GROUND
(
GREEN
) wires together from fan
to
BARE
/
GREEN
wire from ceiling with wire connector
provided.
Since this fan does not come with a light kit, you will
need to cap off the
BLUE
wire with a wire connector (as
shown with arrow in diagram).
[
Note
: If you elect to purchase a light kit for the fan, the
BLUE
wire from the fan must be connected to the
BLACK
wire from the ceiling instead.]
* Wrap each wire connector separately with electrical
tape as an extra safety measure.
wire
connector
black
black
white
white
blue
black supply wire
ground
(green
or bare)
white supply wire
from ceiling
from fan
ground
(green or bare)
*
hanging bracket
screw
canopy
canopy cover
anti-sway
adapter