background image

SAFETY TIPS.

page 1

WARNING

:  To reduce the risk of electrical shock, turn off the electricity to the fan at the main fuse box or circuit panel before you begin the fan 

installation or before servicing the fan or installing accessories.
1.        

 READ ALL INSTRUCTIONS AND SAFETY INFORMATION CAREFULLY BEFORE INSTALLING YOUR FAN AND SAVE THESE 

INSTRUCTIONS.

CAUTION

:  To avoid personal injury, the use of gloves may be necessary while handling fan parts with sharp edges.

2.         Make sure all electrical connections comply with Local Codes or Ordinances, the National Electrical Code, and ANSI/NFPA 70-1999.  If you 

are unfamiliar with electrical wiring or if the house/building wires are different colors than those referred to in the instructions, please 
use a qualified electrician.

3.         Make sure you have a location selected for your fan that allows clear space for the blades to rotate, and at least seven (7) feet (2.13 meters) 

of clearance between the floor and the fan blade tips.  The fan should be mounted so that the tips of the blades are at least thirty (30) 
inches (76 centimeters) from walls or other upright structures.

4.         The outlet box and ceiling support joist used must be securely mounted, and capable of supporting at least 35 pounds (16 kilograms).  

The outlet box must be supported directly by the building structure.  Use only ETL or UL  listed outlet boxes marked "FOR FAN 
SUPPORT."

WARNING

:  To reduce the risk of fire, electrical shock, or personal injury, mount to the outlet box marked "Acceptable for Fan Support of 15.9 kg 

(35 lb) or less," and use the mounting screws provided with the outlet box.  Most outlet boxes commonly used for the support of lighting 
fixtures are not acceptable for fan support and may need to be replaced.  Consult a qualified electrician if in doubt.

WARNING

:  To reduce the risk of fire, electrical shock, or personal injury, wire connectors provided with this fan are designed to accept only one 

12 gauge house wire and two lead wires from the fan. If your house wire is larger than 12 gauge or there is more than one house wire to connect 
to the corresponding fan lead wires, consult an electrician for the proper size wire connectors to use.

WARNING

:  If using this fan in a  WET location, this fan must be connected to a supply circuit that is protected by a Ground Fault Circuit 

Interrupter (GFCI) to reduce the risk of personal injury, electrical shock or death.

5.         Electrical diagrams are for reference only.  
6.         After installation is complete, check that all connections are absolutely secure.
7.         After making electrical connections, spliced conductors should be turned upward and pushed carefully up into the outlet box.  The wires 

should be spread apart with the grounded conductor and the equipment-grounding conductor on opposite sides of the outlet box.

WARNING

:  To reduce the risk of fire or electrical shock, do not use this fan with any solid state speed control device or control fan speed with a 

full range dimmer switch.  [Using a full range dimmer switch to control fan speed will cause a loud humming noise from fan.]
 
8.        Do not operate the reverse switch until the fan has come to a complete stop. [

Note

: If using remote control with reverse capability, reverse 

fan blade direction 

only

 when on LOW speed.] 

9.        Do not insert anything between the fan blades while they are rotating.

WARNING

:  To reduce the risk of personal injury, do not bend the blade arms during assembly or after installation.  Do not insert objects into the 

path of the blades.

WARNING

:  To avoid personal injury or damage to the fan and other items, be cautious when working around or cleaning the fan.

10.      Do not use water or detergents when cleaning the fan or fan blades. A dry dust cloth or lightly dampened cloth will be suitable for most 

cleaning.

WARNING

:  To reduce the risk of personal injury, use 

only

 parts provided with this fan.  

The use of parts 

OTHER

 than those provided with this 

fan will void the warranty.

WARNING

:  

This fan MUST be installed with the safety cable provided with the fan. Failure to use the safety cable provided may result in 

personal injury, damage to the fan or damage to other property.

CAUTION

: Do NOT tamper with or attempt to repair LED component of light kit. The light source is designed for this specific

application and should not be serviced by untrained personnel. If any servicing is required, call our customer service
department.
11.       Light kit is d

immable to 10% with select dimmers.

NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. 

These limits are designed to provide reasonable protection against harmful interference in a residential installation. This

equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may 
cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular 
installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the 
equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

 

* Reorient or relocate the receiving antenna.

 

* Increase the separation between the equipment and receiver.

 

* Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.

Consult the dealer or an experienced radio/TV technician for help.

 

NOTE

:  The important safety precautions and instructions appearing in the manual are not meant to cover all possible conditions and situations 

that may occur.  It must be understood that common sense and caution are necessary factors in the installation and operation of this fan.

Summary of Contents for Mobi MOB60

Page 1: ...on Preparation pg 3 Hanging Bracket Installation pg 3 Fan Assembly pgs 4 5 Wiring pg 6 Canopy Assembly pg 7 Blade Assembly pg 7 Light Kit Assembly pg 8 Handheld Remote Control Assembly pg 9 Automated...

Page 2: ...ING To reduce the risk of fire or electrical shock do not use this fan with any solid state speed control device or control fan speed with a full range dimmer switch Using a full range dimmer switch t...

Page 3: ...ball with pin and clip 1 piece d 4in downrod 1 piece e motor housing 1 piece f yoke cover 1 piece g weatherproof hanging ball cover 1 piece h remote control receiver 1 piece i fitter plate 1 piece j L...

Page 4: ...t towards high point of ceiling Arrange electrical wiring around the back of the hanging bracket and away from the bracket opening Note It is very important that you use the proper hardware when insta...

Page 5: ...pin and clip that were previously removed Tighten yoke set screws and nuts securely Refer to diagram 2 Slide yoke cover and canopy over downrod Refer to diagram 3 Thread safety cable and wires throug...

Page 6: ...cable loop Adjust safety cable length by loosening screw and nut on safety cable vice Adjust slack to a hand s length and tighten nut on vice securely The loop at the end of the safety cable should ju...

Page 7: ...he wall control please proceed to Section 7 page 7 to continue with fan installation To install wall control remove existing wall switch Wire one of the wall controls with wire connectors provided as...

Page 8: ...ing blades Secure all screws lock washers with a Phillips screwdriver Note Tighten blade screws twice a year canopy hanging bracket screw screw motor housing blade blade screw lock washer Locate 2 scr...

Page 9: ...BLACK wire from LED light kit Make sure molex connections snap together completely Remove 3 screws from under fitter plate Carefully arrange wiring within the back of LED light kit Align holes in LED...

Page 10: ...nd press together firmly Place wall control into BOTTOM part of remote control cover aligning posts in top of remote control cover with post holes in the bottom Refer to diagram 3 NOTE Make sure to al...

Page 11: ...ration ON OFF slider switch turns wall control ON or OFF switch not functional on handheld remote HIGH button turns fan to HIGH speed MED button turns fan to MEDIUM speed LOW button turns fan to LOW s...

Page 12: ...is provided please call Customer Support 1 800 486 4892 to request one 2 Check to be sure set screw s on motor housing yoke is are tightened securely 3 Check to be sure set screw on hanging ball is ti...

Page 13: ...nstalaci n del juego de luz P g 8 Ensamblaje del control remoto de mano P g 9 Proceso de aprendizaje autom tico Activar el c digo P g 10 Funcionamiento del control remoto P g 10 Verificaci n del funci...

Page 14: ...iba y colocados cuidadosamente dentro de la caja de salida Los alambres se deben de separar con el conductor a tierra a un lado y el conductor a tierra del equipo al lado opuesto ADVERTENCIA para redu...

Page 15: ...cubierta decorativa 1 unidad b soporte de montaje 1 unidad c tubo de 15 24cm y bola que sirve para colgar con perno y clavija 1 unidad d tubo de 10 16cm 1 unidad e bastidor del motor 1 unidad f cubie...

Page 16: ...rreglar el alambrado el ctrico los cables en la parte de atr s del soporte y lejos de la abertura del soporte Nota es muy importante usar los art culos de ferreter a correctos al instalar el soporte d...

Page 17: ...Referirse al diagrama 2 Deslizar la cubierta del cuello y la cubierta decorativa por el tubo Referirse al diagrama 3 Pasar los cables y el cable de seguridad por la bola que sirve para colgar luego d...

Page 18: ...Ajustar la parte floja del cable de seguridad para que mida como el largo de una mano Apretar bien el tornillo y la tuerca del seguro del cable El bucle del cable debe ser de tal tama o que pase justo...

Page 19: ...vor de pasar a la secci n 7 p gina 7 para seguir con la instalaci n del ventilador Para instalar el control de pared quitar el interruptor de pared existente Alambrar uno de los controles de pared con...

Page 20: ...os arandelas de seguridad con un destornillador de estrella Phillips Nota Apretar los tornillos para las aspas dos veces al a o tornillo aspa bastidor del motor tornillos arandelas de seguridad para e...

Page 21: ...r al cable NEGRO del juego de luz LED Asegurarse de que se conecten bien las conexiones tipo molex Quitar 3 tornillos de la placa de conexi n Cuidadosamente arregle los cables en la parte de atr s del...

Page 22: ...ontrol remoto alineando los postes en la parte superior de la cubierta del control remoto con los agujeros para los postes en la parte inferior Referirse al diagrama 3 NOTA Asegurarse de alinear los e...

Page 23: ...trucciones de la secci n 11 m s arriba bastidor del motor 12 Funcionamiento del control remoto Interruptor corredero ON OFF ENCIENDE y APAGA el control de pared el interruptor no funciona en el contro...

Page 24: ...ara balancear las aspas incluido en uno de los paquetes de art culos de ferreter a Si no se incluye un juego para balancear las aspas llamar al Servicio al cliente 1 800 486 4892 para pedir uno 2 Aver...

Reviews: