4. Hanging Bracket Installation.

Turn off circuit breakers to current fixture from breaker 
panel and be sure operating light switch is turned to the 
OFF position. 

WARNING

: Failure to disconnect power supply prior to 

installation may result in serious injury.

Remove existing fixture. 

WARNING

: When using an existing outlet box, be sure the 

outlet box is securely attached to the building structure and 
can support the full weight of the fan. Ensure outlet box is 
clearly marked "Suitable for Fan Support." If not, it must be 
replaced with an approved outlet box. Failure to do so can 
result in serious injury.

CAUTION

:

 

Be sure outlet box is grounded properly and that a 

ground wire (

GREEN

 or bare) is present.

Partially loosen screws in slotted holes on opposite sides of 
canopy. Remove the other 2 screws--

save for later use

. Twist 

canopy to remove hanging bracket from canopy.

Install hanging bracket to outlet box, using original screws, 
spring washers and flat washers provided with new or 
original outlet box.* Arrange electrical wiring around the 
back of the hanging bracket and away from the bracket 
opening.

*

Note

: It is very important that you use the proper hardware 

when installing the hanging bracket as this will support the fan.

page 3

ON

OFF

ON

OFF

3. Installation Preparation.

To prevent personal injury and damage, 
ensure that the hanging location allows the 
blades a clearance of 7 feet (2.13m) from the 
floor and 30in. (76cm) from any wall or 
obstruction. 
This fan is suitable for room sizes up to 
400  square feet (37.2 square meters).

Installation requires these tools:

Phillips screwdriver, flathead screwdriver, 
adjustable pliers or wrench, stepladder, wire 
cutters, and rated electrical tape.

downrod

installation

flushmount

installation

12f

t - 20f

t

12ft - 20ft

(3.66m - 6.1m)

7 feet

(2.13m)

(76cm)

30 

inches

This fan can be mounted with a 

downrod

on a regular (no-slope) or vaulted ceiling. The 
hanging length can be extended by 
purchasing a longer downrod (0.5in./1.27cm 
diameter). Other installation, such as 

flushmount

, is 

not

 available for this fan.

blade edge

(3.66m - 6.1m)

hanging bracket

spring washers

outlet box screws

flat washers

Vaulted ceiling 
angle is not to 
exceed 19 degrees.  

Summary of Contents for KAT72ESP9

Page 1: ...tents Safety Tips pg 1 Unpacking Your Fan pg 2 Parts Inventory pg 2 Installation Preparation pg 3 Hanging Bracket Installation pg 3 Fan Assembly pgs 4 5 Wiring pgs 5 6 Canopy Assembly pg 6 Blade Assem...

Page 2: ...ms are for reference only Light kits that are not packed with the fan must be CETL or CUL in Canada or ETL or UL in USA listed and marked suitable for use with the model fan you are installing Switche...

Page 3: ...pieces o shade 1 piece p metal cover 1 piece q shade fitter 1 piece r hardware packs page 2 d h m e f a b c 1 Unpacking Your Fan Carefully open the packaging Remove items from Styrofoam inserts Remov...

Page 4: ...riginal outlet box Arrange electrical wiring around the back of the hanging bracket and away from the bracket opening Note It is very important that you use the proper hardware when installing the han...

Page 5: ...he wires together when threading them through the downrod Refer to diagram 2 Determine the length of downrod you wish to use Thread safety cable and electrical wires through threaded end of downrod an...

Page 6: ...n you are now ready to hang your fan Grab the fan firmly with two hands Slide downrod through opening in hanging bracket and let hanging ball rest on the hanging bracket Turn the hanging ball slot unt...

Page 7: ...help PLEASE NOTE Wall and or handheld remote control must be used for fan to operate If you do not wish to use the wall control please proceed to Section 7 below to continue with fan installation To...

Page 8: ...late and attach blade arm with blade arm screws lock washers Before securing screws permanently repeat this procedure with remaining blade arms Securely tighten all screws NOTE Tighten blade arm screw...

Page 9: ...kit if applicable DIMMER SWITCH Dimming capability is determined by the type of bulbs provided with the light kit ON position D OFF position O FAN OFF Use to turn fan off ON OFF slider switch Wall con...

Page 10: ...fan and light batteries have been installed correctly If the wall and or remote control do does not operate the fan light functions refer to Troubleshooting section to solve any issues before contacti...

Page 11: ...llation or use of this product In no case shall the company be liable for any consequential damages for breach of this or any other warranty expressed or implied whatsoever This limitation as to conse...

Page 12: ...2 Preparaci n para la instalaci n P g 3 Instalaci n del soporte de montaje P g 3 Ensamblaje del ventilador P gs 4 5 Instalaci n el ctrica P gs 5 6 Colocaci n de la cubierta decorativa P g 6 Colocaci...

Page 13: ...correcto de conectores para cable que se debe usar 5 Los diagramas el ctricos son nicamente para referencia Los juegos de luz que no se incluyen con el ventilador deben tener el s mbolo CETL o CUL en...

Page 14: ...tilador para una instalaci n adecuada y su seguridad a soporte de montaje fijado de antemano a la cubierta decorativa 1 unidad b cubierta decorativa 1 unidad c tubo con bola que sirve para colgar con...

Page 15: ...ostener el peso total del ventilador Asegurarse de que la caja de salida indique claramente que Sirve para ventilador FOR FAN SUPPORT si no se debe reemplazar con una caja de salida aprobada El no hac...

Page 16: ...seguridad a trav s del extremo roscado del tubo y con cuidado jalar el cableado en exceso por la parte de arriba del tubo Referirse al diagrama 2 Enroscar el tubo en el cuello del bastidor del motor...

Page 17: ...taje a la caja de salida y capaz de apoyar el ventilador usted est listo para colgar el ventilador Agarrar el ventilador firmemente con las dos manos Deslizar el tubo por la abertura del soporte de mo...

Page 18: ...cumple con los l mites para un aparato digital de clase B de acuerdo con la Parte 15 de las Reglas de la FCC Se concibieron estos l mites para proveer protecci n razonable contra la interferencia adv...

Page 19: ...arte inferior del bastidor del motor Colocar la pantalla dentro del conectador para la pantalla y alinear los agujeros Subir el conectador para la pantalla junto con la pantalla o cubierta de metal y...

Page 20: ...de luz si se aplica REDUCTOR DE LUZ Se determina la posibilidad de bajar la s luz luces dependiendo del tipo de bombillas provistas con el juego de luz posici n de ENCENDIDO D positc n de APAGADO O Bo...

Page 21: ...ontrol de pared y o el control remoto no controla todas las funciones del ventilador la luz favor de referirse a la secci n Localizaci n de fallas para resolver cualquier asunto antes de comunicarse c...

Page 22: ...absoluto Esta limitaci n de da os emergentes no se aplicar en estados donde es prohibido Problema El ventilador no funciona Soluciones 1 Inspeccionar el interruptor de pared del ventilador control de...