 7. Wiring.

CAUTION

Be sure outlet box is properly grounded 

and that a ground wire (

GREEN

 or Bare) is present.

Make sure all electrical connections comply with 
Local Codes or Ordinances and the National Electrical 
Code. If you are unfamiliar with electrical wiring or if 
the house/building wires are different colors than 
those referred to in the instructions below, please use 
a qualified electrician.

Note

Excess lead wire length from the fan can be cut 

to the desired length and then stripped.

When fan is secured in place on the hanging 
bracket, electrical wiring can be made as follows:
Connect 

BLACK

 and 

BLUE

 wires from fan to 

BLACK

 wire from ceiling with wire connector 

provided.
Connect 

WHITE

 wire from fan to 

WHITE

 wire from 

ceiling with wire connector provided.
Connect all 

GROUND 

(

GREEN

) wires together 

from fan to 

BARE

/

GREEN

 wire from ceiling with 

wire connector provided.

If you intend to control the fan light with a 
separate light switch connect 

BLUE

 wire from fan  

to the 

BLACK

 (or 

RED) 

supply from the 

independent switch.

* Wrap each wire connector separately with 
electrical tape as an extra safety measure.

This fan is remote control adaptable (remote control 
sold separately).

8. Canopy Assembly.

Temporarily raise canopy to hanging bracket to 
determine which 2 screws in hanging bracket align 
with 

slotted

 holes in canopy, and then lower 

canopy and 

partially loosen

 these 2 screws. 

Remove

 

the 

other

 2 screws and set aside.

Now, lift canopy to hanging bracket again, aligning 
slotted holes in canopy with loosened screws in 
hanging bracket. Twist canopy to lock. Re-insert 
the other 2 screws and secure all screws with 
Phillips screwdriver. 

[

Refer to 

diagram 1

.

Align arrow on canopy ring with the one on the 
canopy. Next, raise the canopy ring over the 
canopy until it is even with the top of the canopy. 
Make sure the canopy and the canopy ring fit 
securely. [

Refer to 

diagram 2

.

]

blue

black

black

white

white

black supply wire

ground

(green

or bare)

white supply wire

*

from ceiling

from fan

ground 
(green or bare)

canopy

canopy

canopy ring

hanging bracket

slotted

hole

diagram 1

diagram 2

Summary of Contents for Helios HE52

Page 1: ...to limit total wattage consumed by the light kit to 190W Therefore this fan is equipped with a wattage limiting device Table of Contents Safety Tips pg 1 Unpacking Your Fan pg 2 Parts Inventory pg 2 I...

Page 2: ...an 12 gauge or there is more than one house wire to connect to the corresponding fan lead wires consult an electrician for the proper size wire connectors to use 5 Electrical diagrams are for referenc...

Page 3: ...ed for repairs Check against parts inventory that all parts have been included 2 Parts Inventory bulb required 1 x 75 watt max halogen bulb type JD E11 included IMPORTANT REMINDER You must use the par...

Page 4: ...bracket opening Note It is very important that you use the proper hardware when installing the hanging bracket as this will support the fan spring washers flat washers outlet box screws hanging bracke...

Page 5: ...end of the downrod Refer to diagram 2 Thread downrod into the motor housing yoke until holes for pin and clip in downrod align with holes in yoke make sure wires do not get twisted Re insert pin and c...

Page 6: ...you once you are set on the ladder Find a secure attachment point wood ceiling joist highly recommended and secure safety cable It will be necessary to use a heavy duty wood screw washer and lock wash...

Page 7: ...lace canopy over yoke aligning larger holes in canopy with the 3 existing screws in top of motor housing Insert the 3 screws and 3 lock washers that were removed if there were only 3 screws located in...

Page 8: ...t switch connect BLUE wire from fan to the BLACK or RED supply from the independent switch Wrap each wire connector separately with electrical tape as an extra safety measure This fan is remote contro...

Page 9: ...enings on motor housing aligning holes in blade with holes in blade arm located on the underside of the motor housing refer to drawing at right Insert 3 blade attachment screws along with washers with...

Page 10: ...screw that was previously removed and tighten all 3 screws securely Install the 75 watt halogen bulb type JD E11 included Tip Do not touch glass portion of bulb with fingers or hands Oil from skin ca...

Page 11: ...Customer Service Turn fan completely off before moving the reverse switch Set reverse switch to recirculate air depending on the season LEFT position in summer diagram 2 RIGHT position in winter diag...

Page 12: ...E ELLINGTON will replace or repair any fan which has faulty performance due to a defect in material or workmanship Contact Craftmade Ellington Customer Service at 1 800 486 4892 to arrange for return...

Page 13: ...e del ventilador P gs 4 6 Instalaci n el ctrica P g 7 Colocaci n de la cubierta decorativa P g 7 Colocaci n de las aspas P g 8 Instalaci n del juego de luz P g 9 Verificaci n del funcionamiento del ve...

Page 14: ...re del cable de la casa es superior al 12 o hay m s de un cable de la casa para conectar a los cables principales del ventilador al cual corresponda cada uno consultar con un electricista para informa...

Page 15: ...verificar que se incluyeron todas 2 Inventario de piezas a cubierta decorativa 1 unidad b soporte de montaje 1 unidad c tubo y bola que sirve para colgar 1 unidad d cubierta del cuello 1 unidad e bas...

Page 16: ...importante usar los art culos de ferreter a correctos al instalar el soporte de montaje puesto que sirve para sostener el ventilador soporte de montaje tornillos de la caja de salida arandelas planas...

Page 17: ...ativa y la cubierta decorativa Referirse al diagrama 3 Nota El anillo de la cubierta tiene que voltearse para que la orilla suave y redondeada quede hacia el bastidor del motor Pasar los cables del ve...

Page 18: ...rado en la escalera para colgarlo Encontrar un punto de acoplamiento seguro se recomienda la viga de madera en el techo y asegurar el cable de seguridad Utilizar tornillo para madera para trabajos pes...

Page 19: ...ecorativa con los 3 tornillos existentes en la parte de arriba del bastidor del motor Introducir los 3 tornillos y las 3 arandelas de seguridad que se quitaron si s lo hab an 3 tornillos en la parte d...

Page 20: ...entilador al conductor NEGRO o ROJO que corresponde al interruptor independiente Como una medida de seguridad adicional envolver cada conector para cable por separado con cinta aisladora Este ventilad...

Page 21: ...angulares en el bastidor del motor alineando los agujeros en el aspa con los agujeros en el brazo para el aspa localizado en el lado inferior del bastidor del motor referirse al dibujo al lado Introdu...

Page 22: ...ojados en la placa de conexi n Girar el conectador para el juego de luz para cerrarlo Volver a introducir el tornillo que se quit anteriormente y apretar bien los 3 tornillos Instalar la bombilla hal...

Page 23: ...uier asunto antes de comunicarse con el Servicio al cliente Apagar el ventilador completamente antes de mover el interruptor de reversa Regularlo para que se circule bien el aire dependiendo de las es...

Page 24: ...ELLINGTON garantiza este ventilador al comprador original de grupo familiar para uso interior con las siguientes condiciones GARANTIA DE 1 A O CRAFTMADE ELLINGTON reemplazar o reparar cualquier ventil...

Reviews: