Step
Possible Cause
If . . .
9
Is there 12Vdc between the ORN-2 wire on
the terminal block left side tenth terminal from
the bottom inside the control box and a
nearby ground?
Yes, go to Step 10.
No, check the length of the ORN-2 wire for
possible damage.
10
Is there 12Vdc between the ORN-1 wire on
the terminal block right side tenth terminal
from the bottom inside the control box and a
nearby ground?
Yes, go to Step11
No, make sure the ORN-1 wire is
completely inserted into the terminal block.
11
Is there 12Vdc between ORN-1 wire on the
Material Pacstat terminal #9 and the ground
BLK-4 wire on the Material Pacstat terminal
#8?
Yes, go to Step 12.
No, check for loose or broken ORN-1 wire
between the terminal block and the Material
Pacstat terminal #9 along with the BLK-4
ground wire.
12
Is there 12Vdc between ORN-1 wire on the
Material Pacstat terminal #1 and the ground
BLK-4 wire on the Material Pacstat terminal
#8?
Yes, go to Step 13.
No, check for loose or broken ORN-1 wire
between the terminal block and the Material
Pacstat terminal #1 along with the BLK-4
ground wire.
13
Is there 12Vdc between ORN-1 wire on the
Material Pacstat terminal #3 and the ground
BLK-4 wire on the Material Pacstat terminal
#8?
Yes, go to Step 14.
No, check for loose or broken ORN-1 wire
between the terminal block and the Material
Pacstat terminal #3 along with the BLK-4
ground wire.
14
Is there 12Vdc between GRY-4 wire on the
Material Pacstat terminal #4 and the ground
BLK-4 wire on the Material Pacstat terminal
#8?
Yes, go to Step15.
No, check for loose or broken GRY-4 wire
between the terminal block and the Material
Pacstat terminal #4 along with the BLK-4
ground wire.
If still no voltage then replace the Material
Pacstat.
15
Is there 12Vdc between the GRY-4 wire on
the terminal block right side first terminal from
the top inside the control box and a nearby
ground?
Yes, go to Step 16.
No, check the length of the GRY-4 wire for
possible damage.
Summary of Contents for SUPER SHOT 60
Page 1: ...Parts Manual 26616 Revision C SUPER SHOT 60 PROPANE MELTER ...
Page 4: ...Super Shot 60 Propane Trailer Melter PN 43300 Super Shot 60 Propane Skid Melter PN 50750 ...
Page 14: ......
Page 22: ......
Page 62: ......
Page 66: ......
Page 102: ......
Page 136: ......
Page 139: ......
Page 140: ... 2018 Crafco Inc ...