Super Shot 60 Propane Melter Part Manual
Chapter 5 Operating Instructions
©2018 by Crafco, Inc. All Rights Reserved
………………..…………………………………..….Operating Instructions 5-15
Step
Action
6
Inside this shot timer box is a knob that controls how long the pump stays running
each time you pull the trigger (1/4 to 5 seconds). Crafco recommends setting the dial
between ¼ and ½ for the shot size.
7
Use the pump speed control to make the final adjustment to the size of the shot
needed for the job.
WARNING
8
While in the “MARKER” mode the material pump turns for the duration of time set by
the shot size dial. Once the wand trigger is pulled the pump will not stop until the time
expires even if the wand trigger is released.
9
When the material flow stops the system is ready to be started again, release the
wand trigger and pull the wand trigger when you are ready for the next shot.
10
At the end of the day use the pump reverse toggle switch located at the rear of the
machine. Reverse the material pump for at least 30 seconds.
Note:
The pump mode does not change the way the pump reverse works.
Shot Timer Troubleshooting Manual
5.12.1
This option comes with an additional manual that covers troubleshooting; electrical schematic and
parts break down. Please refer to this additional manual when needed. This manual is part number
38017N Shot Timer and Trigger Control Kit
Table 5-13 Shot Timer Option (continued)
Summary of Contents for SUPER SHOT 60
Page 1: ...Parts Manual 26616 Revision C SUPER SHOT 60 PROPANE MELTER ...
Page 4: ...Super Shot 60 Propane Trailer Melter PN 43300 Super Shot 60 Propane Skid Melter PN 50750 ...
Page 14: ......
Page 22: ......
Page 62: ......
Page 66: ......
Page 102: ......
Page 136: ......
Page 139: ......
Page 140: ... 2018 Crafco Inc ...