EZ 500 Series II Melter Part Manual
Chapter 8 Troubleshooting
©2019 by Crafco, Inc. All Rights Reserved………………...………………………………..……………...Troubleshooting 8-19
RVP - Pump
Pressure Relief
Set @ 1000 PSI
RVA - Agitator
Pressure Relief
Set @ 1500 PSI
RVHO - Hot Oil Pump
Pressure Relief
Set @ 800 PSI
Jam Nut
Allen Screw
Fig. 8.6 Hydraulic Valve Pressure Setting
Agitation Direction = Counterclockwise
Hydraulic Flow EB/SB= 10.8 GPM @ 2400 RPM
Hydraulic Flow EC/SC = 10.6 GPM @ 2800 RPM
Hydraulic Flow EC/SC = 16.4 GPM @ 2800 RPM
Compressor Relief = 2500 PSI