Faultcode - F214
Incorrect room temperature reading
c
is lit up.
Display text
Room temperature is out of measuring range or sensor is defective.
Solution
Room temperature reading is incorrect. If the room temperature is between
-5°C and 65°C, the temperature sensor may be faulty.
Contact your installer.
Faultcode - F215
Controller failure
c
is lit up.
Display text
Internal fault. Controller failure.
Solution
Contact your installer.
Faultcode - F216
No connection with base station (RF only)
w
and
c
are lit up.
Display text
No communication with base station.
Solution
Check whether the base station for the boiler is on and is functioning
correctly
(consult the transmitter manual if necessary)
. If there is no
connection between the controller and base station, then restore the
connection as follows:
- Put the base station in connection mode
(consult the base station manual
for this).
- On the controller select
Menu > Settings > Users > Connection
.
If this does not solve the problem, look for another location for the controller
and/or base station or remove “obstacles” that could interfere with the RF
signal.