![CR Remeha iSense User Manual Download Page 16](http://html.mh-extra.com/html/cr-remeha/isense/isense_user-manual_2675313016.webp)
16
EN
6. Using the controller
6.1 Selecting program
You can select one of the following programs via
Program
in the main display:
•
Clock program
: the central heating temperature is controlled by the program you have set.
•
Continuous day
: the temperature remains constant at the day temperature you have set.
•
Cont. night
: the temperature remains constant at the night temperature you have set.
•
Frost
: the temperature remains constant at the frost protection temperature you have set. DHW
standby is switched off for this program.
•
Cont. summer
: the temperature remains constant at the night temperature, whereby the tap
water is on standby between 6.00 and 23.00 (which means that you will get hot water more
quickly).
6.2 Temporarily changing the temperature
You can (temporarily) switch off a selected clock program or continuous program at any time by
setting the temperature manually.
1. Turn button C from the main display to set a new temperature.
2. Press
Adjust time
if you also want to set an end time for the manually-selected temperature,
and select this time using push-turn button C.
i
If you do not select an end time and a clock program was active, that clock program will become
active again at the next switch point. Manual operation will then be switched off.
3. Press
Duration
if you also want to set an end date for the manually selected temperature, and
select this time using push-turn button C.