51
The inverter will be shut down immediately if
“OFF” is selected in any cases.
(2) Two languages, i.e. English and Chinese are available in “2 Language”
menu.
(3) Key beep and Alarm beep can be set mute/unmute in
“3 Sounds”
menu
. “Key beep” and “Alarm beep” can be chosen by pressing PAGEUP and
PAGEDOWN. Shift
between “Enable” and “Disable” by pressing Left and Right
if the cursor is on the
“Key beep”. Complete the setup by pressing ENT.
Similarly, the Alarm beep can be set up as well.
(4) Set up the system date and time with “4 SysTime” menu (These
parameters are of critical importance and will be used in history information).
(5) Set the
485 communication parameters with “5 Commun.” menu.
(6) The “6 MPPTScan” menu has three submenus.
1. The first submenu is used to enable/disable the function of MPPT scan
by pressing LEFT or RIGHT. Press ENT to confirm the selection. When the
MPPT scan is enabled, the inverter will scan the MPPT automatically
according to the scheduled cycle.
2. “Cycle(min)” is the second submenu used to set the cycle time of MPPT
scan. Move the cursor to the submenu, press ENT, and use LEFT and RIGHT
to set the cycle time. The range is (30, 540), and the unit is minute. Press ENT
to confirm the selection, or press ESC to get back to the previous menu.
3. “Manual” is the third submenu used to enable the MPPT scan manually.
Move the cursor to the submenu, press ENT to start MPPT scanning.
Note: The function is only effective when the “MPPTScan” is enabled.
(7) “7 ARC Setup” menu has two submenus, ie. “ARC Option” and “ARC
Clear”.
1. “ARC Option” is used to enable/disable the ARC function.
2. “ARC Clear” is used to clear the ARC fault protection. When “ARC
Pro
tect” occurs, the system cannot clear the fault automatically. Please use
“ClearErr” to clear the fault manually.