P/N# 253052002
http://www.cranepi.com
10
8
6
4
2
9
7
5
3
1
15
13
11
16
14
12
INSTALLATION INSTRUCTIONS
(CONTINUED)
5.
Apply power to the vending machine.
•
Observe the LED status indicator on the top of the CXB2 is
ON
and
BLUE
. This indicates
that the unit is ready to accept notes.
•
If the light is OFF, check to ensure that power has been applied.
•
If the light is
RED or BLUE
, refer to the label located on the back of the magazine or the
chart on page 8 for a description of diagnostic codes.
6
.
Check operation
•
Insert a note and observe that it is accepted and stacked.
•
Repeat for other enabled notes.
7
.
Remove the notes and check the status.
•
Instructions for cassette removal are on the label at the back of the magazine.
•
Once the magazine is installed, verify that the LED status indicator remains
BLUE
and
steady
ON
.
PINOUT INFORMATION FOR 16 PIN CONNECTOR
Mating connector:
Dual Row Crimp Connector Housing – Molex
#501646-1600 – 1 pcs.
Female Crimp Terminal - Molex #501647-1000 -16 pcs.
Part Number Description
Pin
Circuitry
1
34VDC(+)
2
34VDC(-)
3
N/C
4
MDB Master Receive
5
MDB Master Transmit
6
MDB Common
7
Auxiliary Channel 2 – RS-232 TXD
8
Auxiliary Channel 2 – RS-232 RXD
9
GND (Communication Ground)
10
+12V Output (for test purposes only)
11
+5V Input (to detect external connection)
12
Auxiliary Channel 1 – RS-232 TXD
13
Auxiliary Channel 1 – RS-232 RXD
14
GND (Communication Ground)
15
Select Line (Auxiliary Input)
16
GND (Communication Ground)