CXB2
Mexico
10
©
CPI 2016
P/N# 253052002
http://www.cranepi.com
DIAGNOSTICS:
If all Bezel lights are in
Solid Red
, block the note path sensors by inserting a bill or piece of
cardboard into the note path and count the number of Diagnostic LED flashes. Then refer to the
diagnostic chart below:
Figure 8
MECHANICAL DIMENSIONS:
The CXB2 note validator is usually installed on a door or a panel. The panel or door must have a
rectangular cut-out and four threaded studs as per diagram below.
## of flashes
Event
1 red on black
Cassette is removed from note validator
2 red on black
Sensor board failure
3 red on black
Cassette is full
4 red on black
Failure of the Stacker mechanism
5 red on black
Failure of the Discrete bill path sensors
6 red on black
Failure of the Optical Array sensor
7 red on black
Failure of the Cross sensor
8 red on black
Failure of the Transport mechanism
9 red on black
Validation data module integrity error
10 red on black Firmware modules incompatibility
11 red on black Note pathway is not empty (bill is jammed)
12 red on black Optical Array sensor is not calibrated
13 red on black Internal 12V Power level is too low
1 blue on red
(boot)
Unable to write program memory
2 blue on red
(boot)
Firmware integrity error
3 blue on red
(boot)
Wrong USB flash drive or firmware update
file is not found
4 blue on red
(boot)
Firmware update file format error
5 blue on red
(boot)
USB OTG I/O error