1019068-C
Page 21
62
62
49
D BA
TTER
Y
D BA
TTER
Y
INSTALLATION
STEP 11.
TESTING
Turn on all gas and electricity to the appliance.
Conduct a gas leakage test of the appliance
piping & control system downstream of the shutoff valve in the supply line to the appliance.
Adjust thermostat to lowest setting.
Place two D Batteries (62) in the Battery pack (49).
A.
Initial startup of the pilot pro system may take several
minutes due to air in the PILOT gas line.
B.
After turning up thermostat, the ignitor will begin to
spark. After 1 minute, it will stop.
C. IF PILOT DOES NOT LIGHT:
Lower thermostat to
OFF
, then turn it back up.
D.
Ignitor will start to spark.
E.
Repeat 11-B through 11-D until the pilot lights.
F.
Visually determine that main burner is burning
properly (i.e., Flame isn't too soft or too hard).
To adjust the primary air shutter(s) as required, see
flame adjustments
on page 25.
!
STEP 12.
TESTING
!
Ensure Ignitor sparks only against
the hood of the pilot.
Look through the sight glass into the chamber. The ignitor
should not spark against the flame sensor, brackets, heating
chamber, burner, etc. Adjust ignitor probe location if required.
- DO NOT twist ignitor wire or break from ceramic base.
- DO NOT use a broken ignitor.