18
18
Blower Button
This key is used to turn the Blower
On/Off. A built-in 20-minute timer will shut
the Blower off unless the user does so manually.
The LED beside the Blower logo on the display will be solid when the Blower is
running. This feature is not available on the Bandit or the Outlaw models.
Light Button
This key is used to turn the Light Switch Off/On. A built-in 2 hour timer will
shut off the light, unless user does so manually.
The LED beside the Light logo will be solid when light is on.
* If the Peyote Light option was installed, repeatedly pushing the light button will
cycle through the different colors.
Filter Button
This key is used to control the Filter cycle. A Filter cycle consists of starting pump
#2 and the blower for 1 minute to purge their plumbing and then start pump one
low speed for the duration of the cycle.
The LED for the Filter logo is solid when there is an active Filter cycle. If the user
presses any key this will suspend the Filter cycle and the LED will flash.
Filter Cycle Duration and Frequency Adjustment
The Filter cycle
Duration
is user programmable. By pressing the Filter key, the display
shows the current duration value “Fdxx”, where xx is from 0 to 2. Using the
Up
and
Down
keys, this value can be adjusted as desired.
The Filter cycle
Frequency
(per day) adjustment is user programmable by pressing an-
other time on the Filter key, the display will show the current frequency value (“FFxx”,
where xx is the frequency). Using the
Up
and
Down
keys, this value can be adjusted from
1 to 4. If a duration of 0 is selected, the Filter cycle never comes on and the Frequency
selection is not offered.
The Default frequency per day is four times a day and the default number of hours per
cycle is one hour.
During the duration adjustment or the frequency per day adjustment, if the user doesn’t
use any key for 5 seconds, the system “stores” the new duration and new frequency, but
these will take effect only at the next Filter cycle. However, if the user exits the duration
or frequency adjustments by pressing the Filter key again, a new Filter cycle is immedi-
ately started, and a new 12-hour cycle is started.