12
12
7.
Install the cable with appropriate connector through the large opening provided in the side
of the control box.
8.
Connect wires, color to color, on terminal blocks TB1. TIGHTEN SECURELY! All wires
must be hooked up or damage could result.
9.
Close the control box door and reinstall the cabinet side panel.
WARNING:
Fill the spa with water before turning on the power.
Once your spa has been filled with water, turn it on and test all of the circuit breakers.
NOTE:
If the GFCI breaker trips immediately, verify that the WHITE neutral wire is connected
into the load neutral in the breaker. Each breaker should be tested prior to each use. Here’s how:
1.
Push the “TEST” button on each GFCI breaker, and observe it click OFF.
2.
Push the breaker switch to the OFF position (to ensure that it has completely disengaged),
then push the breaker switch to the ON position.
If any of the GFCI breakers fails to operate in this manner, your spa may have an electrical malfunc-
tion, and you may be at risk of electrical shock. Turn off all circuits and do not use the spa until the
problem has been corrected by an authorized service agent.
WARNING:
Removing or bypassing any GFCI breaker will result in an unsafe spa and will void the
spa’s warranty.
IMPORTANT:
Should you ever find the need to move or relocate your Coyote Spas™, it is essential
that you understand and apply these installation requirements. Your Coyote Spas™ has been care-
fully engineered to provide maximum safety against electric shock. Remember, connecting the spa to
an improperly wired circuit will negate many of its safety features.