•  Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or 

after the system. 

•  The estimated replacement time of filter, which is a consumable part, is not an indication of quality guarantee period, but 

it means the ideal time of filter replacement. Accordingly, the estimated time of filter replacement may be shortened in 

case it is used in an area of poor water quality.

•  The filtration device installation shall comply with applicable state and local regulations.

•  The reverse osmosis system contains a replaceable treatment component, critical for the effective reduction of total 

dissolved solids and that product water shall be tested periodically to verify that the system is performing properly

•  The influent water to the system shall include the following characteristics:

o No organic solvents

o Chlorine: < 2 ppm

o pH: 7 - 8

o Temperature: 41 °F ~ 95 °F (5 °C ~ 35 °C)

o Iron: < 2 mg/L

o Turbidity: < 1 NTU

o Hardness: < 1 000 mg/L

•  This system has been tested for the treatment of water containing pentavalent arsenic (also know as As(V), As(+5), or 

arsenate) at concentrations of 0.050 mg/L or less. This system reduces pentavalent arsenic, but may not remove other 

forms of arsenic. This system is to be used on water supplies containing a detectable free chlorine residual at the system 

inlet or on water supplies that have been demonstrated to contain only pentavalent arsenic. Treatment with chloramines 

(combined chlorine) is not sufficient to ensure complete conversion of trivalent arsenic to pentavalent arsenic. Please see 

the Arsenic Facts section of this Performance Data Sheet for further information.

•  The compounds certified under NSF/ANSI 401 have been deemed as “incidental contaminants/emerging compounds”. 

Incidental contaminants are those compounds that have been detected in drinking water supplies at trace levels. While 

occurring at only trace levels, these compounds can affect the public acceptance/perception of drinking water quality.

•  Refer to the owner’s manual for specific installation instructions, manufacturer’s limited warranty, user responsibility, and 

parts and service availability.

•  For parts and service availability, please contact your local dealer or Coway.

Model of Filter

Type

Usable period (months)

CNFN8S

NEO-SENSE FILTER

6

CRMFN8S-20

RO MEMBRANE FILTER

20

CIFN8S-PLUS

PLUS INNOSENSE FILTER

18

CAF-03

ANTIBACTERIAL FILTER

12

ARSENIC FACTS

Arsenic (abbreviated As) is found naturally in some well water. Arsenic in water has no color, taste or odor. It must be measured by 

a lab test. Public water utilities must have their water tested for arsenic. You can get the results from your water utility. If you have 

your own well, you can have the water tested. The local health department or the state environmental health agency can provide 

a list of certified labs. The cost is typically $15 to $30. Information about arsenic in water can be found on the Internet at the US 

Environmental Protection Agency website:

www.epa.gov/safewater/arsenic.html

There are two forms of arsenic: pentavalent arsenic (also called As(V), As(+5), and arsenate) and trivalent arsenic (also called As(III), 

As(+3), and arsenite). In well water, arsenic may be pentavalent, trivalent, or a combination of both. Special sampling procedures 

are needed for a lab to determine what type and how much of each type of arsenic is in the water. Check with the labs in your area 

to see if they can provide this type of service.

Reverse osmosis (RO) water treatment systems do not remove trivalent arsenic from water very well. RO systems are very effective 

at removing pentavalent arsenic. A free chlorine residual will rapidly convert trivalent arsenic to pentavalent arsenic. Other water 

treatment chemicals such as ozone and potassium permanganate will also change trivalent arsenic to pentavalent arsenic. A 

combined chlorine residual (also called chloramine) may not convert all the trivalent arsenic. If you get your water from a public 

water utility, contact the utility to find out if free chlorine or combined chlorine is used in the water system.
The CHP-7310R system is designed to remove pentavalent arsenic. It will not convert trivalent arsenic to pentavalent arsenic. The 

system was tested in a lab. Under those conditions, the system reduced 0.050 mg/L pentavalent arsenic to 0.010 mg/L (ppm) (the 

USEPA standard for drinking water) or less. The performance of the system may be different at your installation. Have the treated 

water tested for arsenic to check if the system is working properly. The RO component of the CHP-7310R system must be replaced 

every 20 months to ensure the system will continue to remove pentavalent arsenic. The component identification and locations 

where you can purchase the component are listed in the installation/operation manual.

Summary of Contents for CHP-7310R

Page 1: ...tration Device CHP 7310R This product can not be used if the voltage is different from that mentioned in the rating plate For your safety and proper use of the product please read this User s Manual b...

Page 2: ...er precision extraction function Hygiene improvement for water purifier through utilization of UV LED technology UV LED is activated when extracting cold ambient water to improve hygiene within faucet...

Page 3: ...CONTENTS COWAY Product Information How to Use Maintenance Others 03 Safety Information 07 Parts Name 08 Water Filtration Process 09 Please Check Before Use 10 Buttons and Indicators 18 How to Get the...

Page 4: ...is risk of electrocution and fire Do not pull on the power cord There is risk of electrocution and fire Do not pull on the power cord to move the product There is risk of electrocution and fire Do not...

Page 5: ...lace the damaged power cord and contact the service center to replace the power cord There is risk of electrocution and fire Do not install near electric heating device There is risk of fire Do not in...

Page 6: ...isk of electrocution and fire Do not place candles or cigarettes on top of the product There is risk of fire Do not place bowl filled with water chemicals food small metals or flammable substances on...

Page 7: ...hrough membrane does not contain ion substances which may be inappropriate for living environment of fish There is risk of fish mortality depending on the circumstances There may be residual fine blac...

Page 8: ...Condenser Back cover Tap water input hose Orange Residential water output hose Blue Connector for cooking water Power cord Water Filtration Device CHP 731 0R Before operating the unit please read this...

Page 9: ...function of removing particulates dissolved organic and inorganic impurities It also has another function to remove chlorine volatile organic compounds VOC s Step 3 Membrane filter RO RO Membrane fil...

Page 10: ...and drain it completely twice or more before use Regular filter replacement Regular filter replacement is crucial for drinking clean water Using expired filter decreases water filtration device perfor...

Page 11: ...0ml 1000ml 1500ml continuousextraction CON Displays temperature of hot water 5 Temperature indicator Indicatorturnsononcehotwateris selected PLEASE CHECK BEFORE USE BUTTONS AND INDICATORS How to Use 2...

Page 12: ...tor Indicatoristurnedonwhenthewater levelofthehotwatertankisbelowlowlevel 7 Hot water status indicator Indicatorturnsonaccordingto temperatureofhotwater Morelightsondisplayindicateshottertemperature 8...

Page 13: ...s indicator Indicatorturnsonaccordingto temperatureofcoldwater More lights on display indicates cooler temperature 17 Extraction indicator Itturnsonwhenfilteredwater coldwater isbeingextracted Indicat...

Page 14: ...cthotwater 3 Hot water temperature Extraction control dial Usewhenyouwishtocontrolhotwater temperature extractionamount Turndialtothelefttoselectlower temperature lesserextraction amountand turndialto...

Page 15: ...ion button 8 Extraction amount button 6 Water filtration button 7 Cold water button 10 Function ON OFF button 8 Extraction amount button Usewhenyouwishtoselectdesired extractionamount Continuousextrac...

Page 16: ...becontrolledin6levels 40 50 60 70 80 90 and turningthedialtotherightincreasesthetemperatureandturningthedialtotheleftdecreasesthetemperature Configuring extraction amount for hot water Press hot water...

Page 17: ...to select the temperature you want 3 Press hot water button When extraction amount indicator is displayed turn the dial again to set the extraction amount you want 4 Press and hold the memory button y...

Page 18: ...water function Using filtered water function Press water filtration button and check that the water filtration function indicators are turned on the display unit Using power saving mode Pressing powe...

Page 19: ...ER Press cold water button then press the extraction button Press water filtration button then press the extraction button How to Get Cold Water How to Get Ambient Water If cold water is not being dis...

Page 20: ...tainamountofhotwaterandcoldwater Thisproducthasbeenconfiguredtoproducewarmwaterwhentheindicatorsofhotwaterandcold watertemperatureareturnedontothemaximumlevel Therefore thewatermaybehotterorcolderthan...

Page 21: ...electric outlet Installation Guide Tap water valve Connect the orange tap water input hose to 1 the water pipe Connect 2 the wasted water output hose Tap water input hose Orange connection Cooking wat...

Page 22: ...fter installing the water filtration unit Filter the water for more than 50 minutes or fill and drain once before using the unit Drain the filtered water more than twice Cold water tubing Make sure th...

Page 23: ...valve 2 Presscoldwaterbutton 1 continuousextractionamountbutton 2 andextraction button 3 tocompletelydischargethewaterinsidethewaterfiltrationdevicethrough thedraininghose 3 Disconnect the power plug...

Page 24: ...ehotwaterdischargepipe RED 5 Pushuppercoveroftheproducttoopen openthefixtureclips 6 ontheinternalwatertank andliftuptheinternalwatertankcovertoopen 6 Rotateantibacterialfilterontheinternalwatertankcov...

Page 25: ...ilterintotheinternalwatertankcover closetheinternalwatertankcover andclosefixture clips 6 oftheinternalwatertank 10 Closethedoorsidecoveroftheuppercover andopenthetapwatervalve Checkthat waterisbeingd...

Page 26: ...product and push gently How to Clean the Tray Please shut the internal water tank cover completely Bugs and debris may enter the product Do not use chemicals or detergents when cleaning internal water...

Page 27: ...may vary within the range of expected replacement cycle depending on the feed water quality FILTER REPLACEMENT CHP 7310R Filter Name Expected Replacement Cycle Reverse Osmosis Neo sense filter 6 mont...

Page 28: ...21 2 Use a screw driver to loosen the two screws on the door side cover 3 Please disconnect the fitting connected to the filter you wish to replace and replace the filter Use appropriate tool to disc...

Page 29: ...er Please assemble after cleansing with Neo sense filter for about 1 minute Membrane filter RO After cleansing with the main water passed Neo sense filter for about 5 minutes please assemble it Plus I...

Page 30: ...request for filter replacement Is the power connected Please check that the power cord is connected to 220 V 240 V 50 Hz outlet Is the tap water valve locked Please open the tap water valve Is the tem...

Page 31: ...r is on Please check again after low water level indicator is off Is the power saving mode indicator turned on The water may be less hot than usual when power saving mode is on Is the tap water valve...

Page 32: ...8 L Cold water 2 3 L Hot water 3 4 L Total 13 5 L Filter Material Neo sense filter Activated carbon block Membrane filter RO Reverse osmosis Plus Inno sense filter Activated carbon block non woven fa...

Page 33: ...ColdWater Extraction HotWater Extraction HotWater Drain Color of cap RED Extraction Drain For Power Failure Color of cap BLUE DiskValve HotWater ExtractionValve Temperature Sensor Warm water ColdWater...

Page 34: ...5 3 Aesthetic Chlorine 2 0 10 50 Reduction 79 2 VOC 0 300 10 95 Reduction 99 7 Meprobamate 0 0004 20 0 00006 95 1 Phenytoin 0 0002 20 0 00003 96 5 Atenolol 0 0002 20 0 00003 95 Carbamazepine 0 0014 20...

Page 35: ...ty and parts and service availability For parts and service availability please contact your local dealer or Coway Model of Filter Type Usable period months CNFN8S NEO SENSE FILTER 6 CRMFN8S 20 RO MEM...

Page 36: ...hexachlorobutadiene 0 044 98 0 0013 hexachlorocyclopentadiene 0 05 0 060 99 0 0000023 lindane 0 0002 0 055 99 0 000013 methoxychlor 0 04 0 050 99 0 00013 pentachlorophenol 0 001 0 096 99 0 0013 simazi...

Page 37: ...36 35 PERFORMANCE DATA SHEET CHP 7310R Others MEMO...

Page 38: ...MEMO...

Page 39: ...Others 38 37 MEMO...

Page 40: ...www coway com 9232463 001...

Reviews: