background image

20

Display

UV cycle mode is operation, then Cycle is “ON”

Cycle

U3

U2

Power is on, then U1, U2, U3 is “ON”.
UV cycle mode is operation, then U1, U2, U3 is 
flickering.

U1

Display condition

Segment

< UV cycle segment >

U1

U2

U3

COLD II mode is operation, then C2 is “ON”.

Display

COLD II mode is operation, then C2 is “ON”.

COLD II

C2

Power is on, then C1 is “ON”.

C1

Display condition

Segment

< COLD II segment >

C1

C2

Water Level sensor Middle is on, then L2 is “ON”.
Water Level sensor is open or short, then L2 is 
flickering.

L2

Water Level sensor High is on, then L3 is “ON”.
Water Level is overflow, then L3 is flickering.

Display

Power is “ON”, Then water level is “ON”.

Water

Level

L3

Water Level sensor Low is on, then L1 is “ON”.
Feed water don’t flow, then L1 is flickering.

L1

Display condition

Segment

< Water Level segment >

L1

L2

L3

* Water Level sensor High is open, then L1/L2/L3 is flickering.

Summary of Contents for CHP-01AL

Page 1: ...0 A S...

Page 2: ...verse Osmosis System Operation Method Cleaning Method Specifications of Main Parts Operational Principles Troubleshooting Caution to be Taken at Assemble and Disassemble Replacement of Each Component...

Page 3: ...not pull the power plug from the outlet with a wet hand or get the plug wet to avoid electric shock Never splash the water filtration system with water to avoid the risk of electric shock Keep the co...

Page 4: ...d water pipe Do not run hot water over 104 40 through it It will defect the filters of the water filtration system Periodical filter replacement is prerequisite for getting clean water In case filters...

Page 5: ...Capacity Per Day 14 Silver Activated Carbon 14 Activated Carbon 14 Polypropylene Stainless Steel Filter Reverse Osmosis With Pump Filtration Method 4 9 14 5 23 7 Tank Capacity 868 W Power Consumption...

Page 6: ...5 Features of CHP 01AL As the waterspout can be easily attached or detached it is very convenient when a large amount of water is taken at a time...

Page 7: ...6 Names of Parts...

Page 8: ...7 Indication Parts Operating Parts...

Page 9: ...8 Wiring Diagram Water Flow Diagram...

Page 10: ...Membrane Filter The reverse osmosis filter reduces cryptosporidium viruses coliform bacteria radioactive radon ethylene glycol anti freeze arsenic copper iron lead manganese as well as dissolved chem...

Page 11: ...Accordingly the estimated time of filter replacement may be shortened in case it is used in the area of poor water quality or in case it is used a lot 12 18 month Post Carbon Filter When the UV lamp...

Page 12: ...ved and severely shaken about 30minutes are needed for stabilization of cooling device before using the product Note Note How to Drink Hot Water Installation of the water filtration system must comply...

Page 13: ...forward the cup touch lever of hot or cold water faucet to Extract continuously water Draining Water Open the switch cover on the front and turn off the cold and hot water switch Before unplugging pow...

Page 14: ...13 How to Use Water Spout...

Page 15: ...ng Method Note Note Keep the surrounding environment clean all the time and clean the inside of the tank once a month to get clean water After cleaning drain the first filtered water before drinking t...

Page 16: ...on 25 20psi Material Polyamide Polysulfone Pore size 0 0001 m Feature Various contaminating inorganic substances including bacteria and virus are reduced through fine pores of 0 0001 in diameter 6 Po...

Page 17: ...ressure Switch L P S Use It controls the operation of Boost Pump On Off Operation Principle In the case of low water pressure it makes the pump stopped for prevention of running idle As the water pres...

Page 18: ...he switch is On cooling mode is selected and compressor starts to cold water temperature Cold II Cold Water Selection Switch As the switch is On Cold II cooling mode is selected and it is used for ext...

Page 19: ...NOS Valve Feed water control when is overflow 24Vdc 0 25A UV Pump Circulating the stored water 12Vac 0 3A Circulation Pump Circulating the cool water 24Vac 0 5A Boost Pump Pressurizing feed water 24V...

Page 20: ...rature after main power is On H2 58 59 H7 66 67 H8 73 Off 69 On 69 73 H9 Heater Off On Segment 2 FND Operation 3 8 Off 7 0 On 7 0 8 3 8 Remarks 9 7 C7 11 10 C6 14 13 C5 18 17 C4 C9 5 C8 22 21 C3 C2 Al...

Page 21: ...en C1 is ON C1 Display condition Segment COLD II segment C1 C2 Water Level sensor Middle is on then L2 is ON Water Level sensor is open or short then L2 is flickering L2 Water Level sensor High is on...

Page 22: ...ion Temperature of Sensor 3 Error Display to Inferior Hot Water Sensor Normal Normal operation as detecting normal operation of hot water sensor Recover Off H1 H2 on indicator of hot water temperature...

Page 23: ...Condition 3 of Compressor On Compressor operates after 5 minute on re starting Rage of temperature sensing error below 0 5 4 Error Display to Inferior Cold Water Sensor Normal Normal operation as dete...

Page 24: ...Temperature Control Off LED of Cooling Off Compressor Forced Off 3 Delay of Operation Starting Compressor operates after 5 minute to avoid a damage of main and supplement coil from over current 4 Over...

Page 25: ...ND cable NO YES NO NO Out voltage from transformer S 1 23 1 Vac S 2 12 5 Vac Check the voltage and power failure Replace transformer Check FND cable and replace it Check main PCB and replace it Electr...

Page 26: ...hydro pressure over 10psi Is the electric resistance of LPS 0 Is the connector of LPS showed trace of water Is the voltage value of micom 21st pin The same with table 2 1 PCB normal after changing Is...

Page 27: ...fter replacing main PCB Is the water level sensor accurate connected Unskilled connection of water leverlsensor Inferior input power Inferior water level sensor middle Inferior PCB circuit Check the r...

Page 28: ...wire of water level sensor high short or disconnected Is the signal of water level sensor high exact level high ON 0 level high OFF Is the voltage value of PCB MICOM 5th pin same with table 3 Check af...

Page 29: ...e function of water level sensor normal Is the voltage value of transformer AC24V DC 24V Is the voltage value of Feed valve DC24V Is the function of Feed valve normal when it supplied 24V Check after...

Page 30: ...al Is the flow rate lf plus sediment normal Clogging the plus sedi ment filter Unskilled operation of adaptor Inferior transformer No condition to filtrate Inferior control PCB Inferior Feed valve Inf...

Page 31: ...icator of cold water temperature flickering Does the resistance value of sensor for cold water correct Is terminal voltage of compressor 120Vac and current is below 3 9A when compressor operators YES...

Page 32: ...N 7 th comp connector 120Vac Does the C9th of FND be extinguished It is a mistake of opera ting if swich is OFF It s not operating condi tion if the C9th is not extinguished Inferior CN7 th connector...

Page 33: ...k Is the bi metal connector of hot water tank short Is the heat s resistance value 22 26 Is CN4th voltage value of PCB 120Vac Is the hot water switch ON Not operating hotwater switch Error hotwater se...

Page 34: ...nector Not operating temperature switch ON Heater is OFF if low level LED is extinguished Bi metal is OFF if the heating tank is over heating or bi metal is inferior Error IC 6th and PCB micom Check a...

Page 35: ...ioned away from sharp edge heat source and movable equipment Some electric components are insulated for the safety Let the wirings of the electric component be on the original position The wires and b...

Page 36: ...ngs and replace the filters Pull forward the filter clip to replace the membrane filter and pre carbon filter After replacing the Membrane Filter Drain the filtered water in the storage tank 2 times b...

Page 37: ...ew the front top enclosure Step2 Step4 Disassemble the UV module then replace a new one Unscrew the PCB cover Then separate the connector of UV module from PCB ass y Step3 Separate the silicon tube fr...

Page 38: ...37 3 Clean the Main tank Step1 Step2 Open the top enclosure and tank cap Disassemble the separate M and cold water supporter Step3 Clean the tank with fiber tissue...

Page 39: ...38 4 Replacement of Main PCB Step1 Step2 Step3 Unscrew the PCB cover Separate the connector from PCB Open the front bottom enclosure Then unscrew the front top enclosure Step4 Replace the PCB ass y...

Page 40: ...39 5 Replacement of feed valve LPS N O S Step1 Step2 Step3 Unscrew the right side of filter clips Pull the filter clip Then replace LPS Feed valve N O S Open the front bottom enclosure...

Page 41: ...40 6 Replacement of compressor PTC OLP Step1 Step2 Step3 Unscrew and open the protector Then separate the comp cable Replace PTC OL Open the front bottom enclosure...

Page 42: ...41 7 Replacement of fuse Step1 Step2 Step3 Open the fuse holder Step4 Replace the new one Open the front bottom enclosure Unscrew the right side of filter clips...

Page 43: ...pump Step1 Step2 Step3 Unscrew the boost pump Then disassemble the tube on the boost pump Open the front bottom enclosure Unscrew the right side of filter clips Then pull the filter clip Step4 Replac...

Page 44: ...Disassemble silicon tube of circulation pump after binding the silicon tube Disassemble connector of circulation pump Then unscrew the circulation pump Open the front bottom enclosure Then disassemble...

Page 45: ...44 10 Replacement of bi metal thermistor Step1 Step2 Step3 Disassemble connector on the bi metal Unscrew bi metal and replace it with new one Unscrew the side door on left side panel...

Page 46: ...45 11 Replacement of transformer Step1 Step2 Step3 Unscrew the transformer Disassemble the connector of transformer on PCB Unscrew the rear enclosures Step4 Replace the transformer with new one...

Page 47: ...ector of reed level sensor which wanted to replace on PCB Replace the reed level sensor what you want Open the top enclosure Then disassemble connector of overflow sensor When you change the reed leve...

Page 48: ...13 Replacement of overflow connector Step1 Step2 Step3 Disassemble connector of overflow sensor Then remove connector cap and unscrew Replace the overflow connector with new one Open the top enclosur...

Page 49: ...8 14 Installation of drain tube to use Step1 Step2 Step3 Connect the drain tube to nipple on the tray Then bind it with clip Pass the drain tube out of drain port Disassemble the front bottom enclosur...

Page 50: ...49 Harness Diagram...

Page 51: ...50 Harness Diagram...

Page 52: ...ter source to Innowave s water filtration system must adapt to 1 4 tubing This installation manual includes the contents from installation and product use Do not use any kinds of filters and component...

Page 53: ...ong distance could result to twisting the tubing to cause abnormal water filtration process Keep the water filtration system out of direct sunlight The sun s heat may distort non metallic parts and ma...

Page 54: ...e to water filtration system For connection from the water pipe to water filtration system One of end side is closed Fittings Type T Elbow Type Straight Type Stem Elbow Type For connecting tubing with...

Page 55: ...pen end wrench to tighten the adaptor Step4 Do not wrench the water pipe Step5 Step6 Step7 Connect the faucet with the adaptor Open main water supply valve or screw up the controller on the faucet lik...

Page 56: ...Installation Manual Saddle Valve Type Case 1...

Page 57: ...Installation Manual...

Page 58: ...rnings previously mentioned Step1 Separate the tubing behind the plus sediment filter Step2 Step3 In the initial installation and filter replacement connect the pre and or post carbon filter behind th...

Page 59: ...RAY EA 1 13 002100280 AIR VENT CAP PP EA 1 14 002200460 FEED VALVE DC24V EA 1 15 002201510 OVERFLOW SENSOR M4x29 SUS316 EA 2 16 004600180 COOLING STOPPER ABS EA 2 17 004603510 SIDEBUSH PE 29 EA 4 18 0...

Page 60: ...PCB BRACKET PP V0 UL EA 1 41 004900400 TANK BRACKET 1 2t EA 1 42 004900470 COOL COCK INSULATION EA 2 43 004900480 HOT COCK INSULATION EA 1 44 004900530 SILICON M T H T EA 1 45 704900370 SILICON C T C...

Page 61: ...61 704900310 TRANSFORMER UL 23 1VAC 1 5A 12 5VAC 0 5A EA 1 62 004900940 BOOSTER PUMP CDP 2000 AC 24V EA 1 63 005700620 CIRCULATION PUMP DC24V EA 1 64 704900320 UV CIRCULATION MODULE UL ASSY EA 1 70490...

Page 62: ...540 SILICON C T DRAIN2 EA 1 004900550 SILICON H T DRAIN2 EA 1 004901380 DRAIN COVER PP EA 1 004901630 POWER SWITCH 15A 250VAC SERIES R5 EA 1 104790070 CABLE TIE 100A DAMB 100A EA 2 104790120 CABLE TIE...

Page 63: ...700300780 Compressor LX72LBQG R134a 115V 60Hz 1 4HP LG EA 1 104135040 CASTER A EA 2 104135050 CASTER B EA 2 901121010 SCREW TAPPING A TH T2 4x8 MSWR Ni P EA 2 901122310 SCREW TAPPING TH T2 4x10 BLACK...

Page 64: ...A 1 106 107293060 PRESS SEALANT 50X60 mm EA 1 107 901113040 SCREW MACHINE PH M6x16 SUS EA 3 108 901121030 SCREW TAPPING TH T2 4X12MSWR Ni P EA 17 109 901122030 SCREW TAPPING PH T2 4X8 Ni P EA 2 110 90...

Reviews: