Electrical specifications
3) The Covana cover requires a dedicated single-phase 115 VAC (North America) or 220 VAC (European) hard-
wired power supply.
4) The Covana cover must be installed in accordance with and comply with all the applicable local codes and
regulations. All wiring and connections should be performed by a qualified electrician.
5) Wires and conduits should be sized according to the local codes and regulations.
North American requirements:
Voltage
115 V, 60 Hz (1 hot, 1 neutral, 1 ground)
GFCI
15 A single-pole GFCI (not included)
Current draw
Max. 12 A
European requirements:
Voltage
220 V, 50 Hz (1 hot, 1 neutral, 1 ground)
GFCI
10 A single-pole GFCI (not included)
Current draw
Max 6 A
Operating limitations
WARNING
6) The Covana cover should never be used if the following conditions are reached.
Maximum wind
Gusts of 20 mph (30 km/h) while in the raised position
and 45 mph (70 km/h) when completely lowered on the
hot tub.
Maximum weight on the cover (evenly distributed)
120 lb. (54 kg)
General specifications
Lifting speed
2.5 in./s (6.35 cm/s)
Total weight
530 lb. (240 kg)
Stock key switch cable
25 ft. (7.6 m)