background image

STOP    

DO NOT RETURN TO THE STORE!

PAGE 2 OF 8

Keep the appliance area clear and free from 

combustible materials, gasoline, and other 

flammable vapors and liquids.

Solid fuels should not be burned in this gas

appliance.

Inspect the hose before each use of the appliance. 

The hose assembly must be replaced prior to the 

appliance being put into operation if there is 

evidence of excessive abrasion, wear, or if the 

hose is damaged. The replacement hose assembly

is specified in this manual. 

The burner must be inspected before each use. 

The burner must be replaced prior to the appliance 

being put into operation if it is evident that the 

burner is damaged. The replacement burner is 

specified in this manual.

The burner should always be cleaned:

Disconnect it from the appliance, use a cleaner to 

remove blockages attached on the ports, and drain 

the blockages from the gas inlet. A high pressured 

stream of water may also be used.

Do not use this appliance if any part has been 

under water. Immediately call a qualified service 

technician to inspect the appliance and to replace 

any part of the control system and any gas 

control that has been under water. 

This appliance is for outdoor use only in a 

well-ventilated space and should not be used in 

a building, garage, or any other enclosed area. 

Other cylinders may be acceptable for use with the 

appliance provided that they are compatible with the 

appliance retention means and accompanied by

illustration(s) depicting the cylinder mounted to the 

appliance utilizing the cylinder retention means and

the point of contact between the cylinder and the 

retention means. The cylinder should be 12 inches

in diameter and 18 inches high. The capacity is 

20lbs of propane.

If the appliance is not in use, the gas must be turned 

off at the supply cylinder. 

Storage of an appliance indoors is permissible only 

if the cylinder is disconnected and removed from the 

appliance. 

Cylinders must be stored outdoors in a well-ventilated 

area and out of children’s reach. 

Disconnected cylinders must have a dust cap 

secured at the end of the valve and cannot be stored 

in a building, garage, or any other enclosed area. 

The pressure regulator and hose assembly supplied 

with this appliance must be used. Replacement 

pressure regulators and hose assemblies must be 

the ones specified in this manual.

The cylinder supply system must be arranged for 

vapor withdrawal. 

The cylinder used must include a collar to protect 

the cylinder valve.

The Procedure for Checking for Gas Leaks:

Never test for leaks with a flame. Prior to first use, at 

the beginning of each season, or every time your LP 

gas tank is changed, you must check for gas leaks.

Follow these three steps:

1.  Make a soap solution by mixing one part liquid 

    detergent and one part water.

2.  Make sure that the burner is off and then turn the 

    gas on at source. 

3.  Apply the soap solution to all gas connections, 

    especially to the inlet/manifold pressure tap on the 

    gas valve after reading the pressure. Bubbles will 

    appear in the soap solution if the gas connections 

    are not properly sealed. If you have a gas leak, 

    tighten gas connections, turn off the gas at the 

    source, disconnect the fuel line from your appliance,

    and call 1-877-539-7436 for repair assistance.

WARNING

!

WARNING

!

WARNING

!

WARNING

!

The LP-gas supply cylinder to be used must be:

1. Constructed and marked in accordance with the 

    U.S. Department of Transportation (D.O.T.) 

    Specifications for LP-Gas Cylinders, or the 

    Standard for Cylinders, Spheres and Tubes for

    Transportation of Dangerous Goods; and 

    Commission, CAN/CSA-B339 as applicable;

2. Provided with a listed overfilling prevention device;

3. Provided with a cylinder connection device 

    compatible with the connection for the appliance.

Locate the gas hose and make sure that it is not in any 

pathways where people may trip over it or in any areas 

where the hose may be subject to accidental damage.

When an appliance is for connection to a fixed 

piping system, the installation must conform with

local codes or, in the absence of local codes, with

the National Fuel Gas Code, ANSIZ223.1 NFPA 

54; National Fuel Gas Code; Natural Gas and 

Propane Installation Code, CSA B149.1; or 

Propane Storage and Handling Code, CSA 

B149.2, as applicable. 

V-3

Summary of Contents for TMS54GM

Page 1: ...s and liquids in the vicinity of this or any other appliance An LP cylinder not connected for use shall not be stored in the vicinity of this or any other appliance DANGER If you smell gas 1 Shut off...

Page 2: ...d cylinders must have a dust cap secured at the end of the valve and cannot be stored in a building garage or any other enclosed area The pressure regulator and hose assembly supplied with this applia...

Page 3: ...open all of the packaged cartons Lay out all of the parts on a level non abrasive surface Open the hardware kit for all of the nuts bolts and washers Make sure that you have all of the parts listed If...

Page 4: ...nnector 7 See Figure 3 Note The lower connector 7 is marked with an E Note 1 Close the front door to ensure proper assembly See Illustration A 2 When moving the appliance make sure that the front door...

Page 5: ...crew Step 6 Open the front door 5 and place the tank into the bottom frame 4 Secure in place by using the plastic screw See Figure 6 Note Secure the tank in place by turning the plastic screw clockwis...

Page 6: ...afety of your appliance 5 When not in use we recommend that it be stored in a dry and secure area Always disconnect the LP gas tank first and store it safely outside 6 The minimum clearance from the s...

Page 7: ...first and store it safely outside 7 LP gas tanks must be stored outdoors in a well ventilated area and out of children s reach Disconnected LP gas tanks must not be stored in a building garage or any...

Page 8: ...port assembly and through the tank fastener See Figure B Note To replace the tank repeat Step 6 and Step 7 in the assembly instructions NOTE You must make periodic checks to ensure that all connection...

Page 9: ...solina u otros vapores o l quidos inflamables cerca de este ni otros equipos dom sticos No almacene cilindros de gas LP que no est n conectados al equipo cerca de este ni de cualquier otro equipo dom...

Page 10: ...incluyen con este equipo Los reguladores de presi n y las mangueras de repuesto deber n cumplir con las especificaciones que se detallan en este manual El sistema de suministro del cilindro deber conf...

Page 11: ...das las partes en una superficie plana y no abrasiva Abra el kit de accesorios para tener acceso a todas las tuercas los tornillos y las rondanas Aseg rese de que tenga todas las partes que se detalla...

Page 12: ...te la figura 3 Nota El conector inferior 7 est marcado con una E Nota 1 Cierre la puerta frontal para verificar que est debidamente armada Consulte la ilustraci n A 2 Cuando mueva el equipo aseg rese...

Page 13: ...4 Tornillo de pl stico Paso 6 Abra la puerta frontal 5 y coloque el tanque en el marco inferior 4 F jelo con ayuda del tornillo de pl stico Consulte la figura 6 Nota Fije el tanque en su lugar girand...

Page 14: ...empre desconecte primero el tanque de gas LP y gu rdelo en un lugar seguro afuera 6 La distancia m nima que debe haber entre los costados y las partes trasera y superior de la unidad y una construcci...

Page 15: ...ning n lugar cerrado Siempre desconecte primero el tanque de gas LP y gu rdelo en un lugar seguro afuera 7 Los tanques de gas LP deben guardarse en exteriores en un lugar bien ventilado y fuera del al...

Page 16: ...p selo por el sujetador del tanque Consulte la figura B Nota Para cambiar el tanque repita los pasos 6 y 7 de las instrucciones de armado NOTA Haga revisiones peri dicas para asegurarse de que todas l...

Reviews: