REMINDER:
The chimney must extend at least three feet above the highest point
where it passes through the roof of a building. The chimney must be at
least two feet higher than any portion of a building within ten feet of the
chimney. Refer again to Figure 5 for clarification.
Install the flashing, storm collar and the chimney cap following the chimney manufacturer’s
instructions.
Refer to the chimney manufacturer’s requirements concerning supports, bracing, anchors, and
other required material.
Figure 23, Figure 24, Figure 25, and Figure 26 are provided as reference examples for different
chimney installations. Please refer to the chimney manufacturer’s instructions for proper
installation of the type chimney being installed with the Inglenook Fireplace.
FIGURE 23: EXAMPLE CHIMNEY INSTALLATION (Interior Space)
Version: 7.0
34