3. Instructions

 

BP-

□□□□

A

 

series are high frequency switch-mode 3-stage battery chargers 

equipped with micro-controller and PFC circuit to manage battery intelligently 

and to provide highly reliable operations.    Before using BP-

□□□□

A

read all 

instructions and precautions marking on this manual. 

3-1. Front Panel Operation

 

3-1-1.Front view

 

0N

0FF

0

I

AC INPUT

 

 

I
0

0FF

AC INPUT

0N

 

 

 

 

 

IEC RECEPTACLE TYPE

POWER CORD TYPE

6

Summary of Contents for BP-1205A

Page 1: ...BP A Series Switch Mode 3 Stage Battery Charger User s Manual...

Page 2: ...g Curve 3 2 2 Electrical Characteristics 4 2 3 Mechanical Drawing 5 3 Instructions 6 3 1 Front Panel Operation 6 3 2 Rear Panel Operation 7 3 3 Troubleshooting 8 3 4 Battery Type Selections 8 Copyrigh...

Page 3: ...mpartment Overheating may occur 1 1 2 To avoid the risk of fire and electronic shock make sure that existing wiring is in good electrical condition and not undersize Do not operate BP A Battery Charge...

Page 4: ...mmediately 1 2 2 Never smoke or make a spark or flame in the vicinity of the battery or the engine 1 2 3 Do not drop metals on the battery The resulting spark or short circuit on the battery or other...

Page 5: ...or Advanced 8 bit microprocessor control circuit Reverse polarity protected by fuse Ignition protection Output short circuit protection Over power protection Switch mode technology Statue of charge in...

Page 6: ...Coefficient 0 03 C 0 50 C Vibration 10 500Hz 1G 0 5Oct min period for 60min Each along X Y Z axes Safety EMC Safety Standards IEC 60950 1 1st Edition 2001 EN 60950 1 1st Edition 2001 A11 Withstand Vo...

Page 7: ...2 3 Mechanical Drawing 5...

Page 8: ...controller and PFC circuit to manage battery intelligently and to provide highly reliable operations Before using BP A read all instructions and precautions marking on this manual 3 1 Front Panel Ope...

Page 9: ...ing Charge Solid Green Charging Failure or Wire Disconnection Red Blink 3 2 Rear Panel Operation STATUS DC OUTPUT PUSH FUSE DC 3 2 1 Ventilation Shaft Be sure to keep it a distance at least one inch f...

Page 10: ...tput fuse LED light off No AC power delivering Check input power connection Thermal shutdown Make sure the ventilation shaft is not obstructed Improve ventilation Lower the temperature Surrounding it...