2-2. Electrical Characteristics

 

Model  

BP-1210A 

BP-1205A 

BP-2405A 

BP-2403A 

Output 

DC Voltage Range 

14.4V 

14.4V 

28.8V 

28.8V 

Rated Current 

10A 

5A 

5A 

2.5A 

Current Range 

0 ~ 10A 

0 ~ 5A 

0 ~ 5A 

0 ~ 2.5A 

Rated Power (max.) 

144W 

72W 

144W 

72W 

Battery Charger Mode 

3 - stage Battery Chargers ( Refer to Battery Charging Curve) 

Indication LED 

Refer to LED Status 

Input 

Voltage Range 

88 ~ 264VAC  

Frequency Range 

47Hz ~ 63Hz 

Efficiency ( Typ. ) at 230Vac 

80% 

78% 

83% 

80% 

AC Current ( Max. )            

1.9 A / 90VAC            0.95A / 180VAC 

Inrush Current ( Typ. ) 

Cold Start  30A / 230VAC 

Leakage Current 

< 0.75mA / 240VAC 

Protection 

Over Load 

102~110%   rated output power 
Protection  type : Const

a

nt  current lim iting,  Hiccup m ode,  recovers a utomatically 

after fault condition is removed 

Over Temperature 

85°C  ± 5°C ( TH1 ) detect on heat sink 
Protection  type  : Shut d own  output  voltage,  recovers  automatically  after 

temperature goes down 

Environment 

Working Temp. 

- 20°C ~ 50°C  

Working Humidity 

20 ~ 90% RH non-condensing 

Storage Temp., Humidity 

- 40 ~ +85°C 

Temp.Coefficient 

± 0.03% / °C ( 0 ~ 50°C ) 

Vibration 

10 ~ 500Hz, 1G 0.5Oct/min, period for 60min. Each along X,Y,Z axes 

Safety  

 &  

 EMC 

Safety Standards 

IEC 60950-1, 1st Edition ( 2001 ) ; EN 60950-1, 1st Edition ( 2001+A11 ) 

Withstand Voltage 

I/P - O/P:3KVAC   I/P - FG:1.5KVAC  O/P-FG:0.5KVAC, 1 minute 

Isolation Resistance 

I/P - O/P, I/P - FG, O/P - FG:100M Ohms/500VDC 

EMI Conduction & Radiation 

EN 55022 : 2006   Class B 

Harmonic Current 

EN 61000-3-2 : 2006 ; EN 61000-3-3 :1995+A1 : 2001+A2 : 2005 ;  

EN 55024 : 1998+A1:2001+A2 : 2003 ; 

EMS Immunity 

IEC  61000-4-2  Edition  1.2 : 2001

-04  ; IEC 6100

0-4-4  : 2004

IEC  61000-4-5  Edition  1.1  : 2001-0 4  ;  IEC 6100 0-4-6  Edition  2.1  : 2004-1 1

IEC 61000-4-8 Edition 1.1 : 2001-03 ; IEC 61000-4-11 Second Edition : 2004-03 

Others 

MTBF  

Compliance: MIL-HDBK-217F   

 

  

Dimension (L*W*H) (mm) 

210 (L) x 85 (W) x 50 (H) mm / 8.26 (L) x 3.34 (W) x 1.96 (H) Inch 

Packing 

1 kg.  /  2.2 Lbs. 

Note 

1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25

 of  

ambient temperature. 

2. The power supply is considered a component which will be installed into a final equipment.  

3. The final equipment must be re-confirmed that it still meets EMC directives. 

 

*Note : The specifications are subject to change without notice. 

4

Summary of Contents for BP-1205A

Page 1: ...BP A Series Switch Mode 3 Stage Battery Charger User s Manual...

Page 2: ...g Curve 3 2 2 Electrical Characteristics 4 2 3 Mechanical Drawing 5 3 Instructions 6 3 1 Front Panel Operation 6 3 2 Rear Panel Operation 7 3 3 Troubleshooting 8 3 4 Battery Type Selections 8 Copyrigh...

Page 3: ...mpartment Overheating may occur 1 1 2 To avoid the risk of fire and electronic shock make sure that existing wiring is in good electrical condition and not undersize Do not operate BP A Battery Charge...

Page 4: ...mmediately 1 2 2 Never smoke or make a spark or flame in the vicinity of the battery or the engine 1 2 3 Do not drop metals on the battery The resulting spark or short circuit on the battery or other...

Page 5: ...or Advanced 8 bit microprocessor control circuit Reverse polarity protected by fuse Ignition protection Output short circuit protection Over power protection Switch mode technology Statue of charge in...

Page 6: ...Coefficient 0 03 C 0 50 C Vibration 10 500Hz 1G 0 5Oct min period for 60min Each along X Y Z axes Safety EMC Safety Standards IEC 60950 1 1st Edition 2001 EN 60950 1 1st Edition 2001 A11 Withstand Vo...

Page 7: ...2 3 Mechanical Drawing 5...

Page 8: ...controller and PFC circuit to manage battery intelligently and to provide highly reliable operations Before using BP A read all instructions and precautions marking on this manual 3 1 Front Panel Ope...

Page 9: ...ing Charge Solid Green Charging Failure or Wire Disconnection Red Blink 3 2 Rear Panel Operation STATUS DC OUTPUT PUSH FUSE DC 3 2 1 Ventilation Shaft Be sure to keep it a distance at least one inch f...

Page 10: ...tput fuse LED light off No AC power delivering Check input power connection Thermal shutdown Make sure the ventilation shaft is not obstructed Improve ventilation Lower the temperature Surrounding it...

Page 11: ...No 33 Rong Hsin Rd Pa Teh City Tao Yuan County Taiwan Phone 886 3 3661581 FAX 886 3 3676029 E mail sales cotek com tw http www cotek com tw 2005 08...

Reviews: