1-2. Battery Precautions 

1-2-1.If battery acid contacts your skin or clothing, you shall wash it out with 

soap and water immediately.    If battery acid contacts your eyes, you 

shall wash it out with cold running water for at 1 least 20 minutes and 

get medical attention immediately. 

1-2-2.Never smoke or make a spark or flame in the vicinity of the battery or 

the engine. 

1-2-3.Do not drop metals on the battery.    The resulting spark or short-

circuit on the battery or other electrical parts may cause an explosion. 

1-2-4.Remove personal metal items such as rings, bracelets, necklaces, 

and watches when operating with lead-acid batteries.    Doing so may 

cause short circuit and very high temperature, which can melt metal 

items and even burn you. 

 

 

 

2

Summary of Contents for BP-1205A

Page 1: ...BP A Series Switch Mode 3 Stage Battery Charger User s Manual...

Page 2: ...g Curve 3 2 2 Electrical Characteristics 4 2 3 Mechanical Drawing 5 3 Instructions 6 3 1 Front Panel Operation 6 3 2 Rear Panel Operation 7 3 3 Troubleshooting 8 3 4 Battery Type Selections 8 Copyrigh...

Page 3: ...mpartment Overheating may occur 1 1 2 To avoid the risk of fire and electronic shock make sure that existing wiring is in good electrical condition and not undersize Do not operate BP A Battery Charge...

Page 4: ...mmediately 1 2 2 Never smoke or make a spark or flame in the vicinity of the battery or the engine 1 2 3 Do not drop metals on the battery The resulting spark or short circuit on the battery or other...

Page 5: ...or Advanced 8 bit microprocessor control circuit Reverse polarity protected by fuse Ignition protection Output short circuit protection Over power protection Switch mode technology Statue of charge in...

Page 6: ...Coefficient 0 03 C 0 50 C Vibration 10 500Hz 1G 0 5Oct min period for 60min Each along X Y Z axes Safety EMC Safety Standards IEC 60950 1 1st Edition 2001 EN 60950 1 1st Edition 2001 A11 Withstand Vo...

Page 7: ...2 3 Mechanical Drawing 5...

Page 8: ...controller and PFC circuit to manage battery intelligently and to provide highly reliable operations Before using BP A read all instructions and precautions marking on this manual 3 1 Front Panel Ope...

Page 9: ...ing Charge Solid Green Charging Failure or Wire Disconnection Red Blink 3 2 Rear Panel Operation STATUS DC OUTPUT PUSH FUSE DC 3 2 1 Ventilation Shaft Be sure to keep it a distance at least one inch f...

Page 10: ...tput fuse LED light off No AC power delivering Check input power connection Thermal shutdown Make sure the ventilation shaft is not obstructed Improve ventilation Lower the temperature Surrounding it...

Page 11: ...No 33 Rong Hsin Rd Pa Teh City Tao Yuan County Taiwan Phone 886 3 3661581 FAX 886 3 3676029 E mail sales cotek com tw http www cotek com tw 2005 08...