Care and maintenance
Good maintenance is essential for safe, economical and trouble-free operation and a long service-life.
Maintenance schedule
Caution!
Never service the generator whilst the engine is running. Switch the generator off and let it cool.
Check
Action
Before
every use
After 1
month or
20 hours
Every 3
months or
50 hours
Every 6
months or
100 hours
Every 12
months or
300 hours
Spark plug
Check, adjust gap
and replace if
necessary
•
Engine oil
Check level
•
Replace
•
•
Air filter
Clean and replace
if necessary
•*
Valve clearance
Check and adjust
when engine is cold
•
Have checked
and adjusted
by qualified
tradesman
Fuel line
Check for cracks
and leaks
•
Carburettor
Check choke
operation
•
Cooling system
Check that the
ventilation openings
are clear
•
Starting system
Check starter cord
for wear
•
Fittings and
fasteners
Tighten all screws
and nuts
•
* If the generator is in a dusty environment, the filter should be cleaned more often.
Engine oil
If the oil level is too low, the generator shuts off automatically to prevent damage. Check the oil level prior to
every use to ensure that there is enough.
Engine oil gradually loses the lubricating, cooling and cleaning properties it has when it is new and therefore
needs to be changed periodically.