Outdoor Unit
1
5. Working Principles
Before
Use
1
6. Specifications
Before
use
1
12
Expansion
Valve
Filter
Refrigerant
Three-Way Valve
Pressure Check
Valve
Power Supply
Compressor
Four-Way Vale
Fan Motor
Evaporator
Model
(1)
(1)
C.O.P
Power Supply - Refrigerant
(
Max.Heating Capacity
(1)
Heating Capacity Min./Max.
(1)
Heating Power Input Min./Max.
(1)
C.O.P Min./Max.
(2)
Max. Heating Capacity
(2)
C.O.P
(2)
Heating Capacity Min./Max.
(2)
Heating Power Input Min./Max.
(2)
C.O.P Min./Max.
(3)
Max. Cooling Capacity
(3)
E.E.R
V/Hz/Ph
KW
W/W
All-In-One Series
KW
W
W/W
KW
W/W
KW
W
W/W
KW
W/W
GB 09
GB 13
220-240/50/1-R410A
10.10
4.03
4.33/10.10
975/2153
4.02/4.65
9.53
3.17
4.19/9.53
1230/2990
3.12/3.55
6.84
2.09
12.6
3.89
4.2/12.6
926/3072
3.89/4.77
11.5
3.08
3.76/11.50
1267/3723
2.97/3.28
10.3
3.29
GB 06
6.06
4.05
2.91/6.06
1.59/4.5
4.05/5.87
5.8
3.22
2.05/5.8
640/1810
3.22-4.12
5.81
3.51