56
COSMOGAS
Ecotwin
8.2.4 - DHW storage
The menu consists of several pages and, by scrolling with the
arrows, it is possible to consult and modify all the parameters
relating to DHW storage:
Figure 8-10 - Sanitary hot water storage timer
Parameter
Permission
level
U.M.
Range
Factory setting
Costum
value
Sanitary hot water storage function (Don’t change)
End user
/
Selected -
Not selected
Not selected
Sanitary hot water storage timer (Don’t change)
End user
/
Reheating function (Don’t change)
End user
/
Selected -
Not selected
Not selected
Reheating function timer (Don’t change)
End user
/
Reheating set temp. (Don’t change)
End user
°C
30...55
35
Reheating restart ΔT setting (Don’t change)
End user
°C
2...20
10
WARNING!!! When setting the “
Sanitary hot water
storage timer
“ and ”
Reheating function timer
“ make sure
that:
-the time bands chosen in these two functions do not
overlap;
- there are no time bands in which neither of the two
functions is inactive; at least one of the two functions
must be active for each time band.
8 - USE
Figure 8-9 - DHW storage icon