13
6 - Installers’ menu
Pressing down key KM for around 10 seconds it is possible to access the menus intended for the installer.
Page 1 makes it possible to make one of the following choices:
· INFO
display the system parameters
· IMP
display and change the system parameters
· ERR
display faults
· >>
Pressing key K4 (>>), access is gained to page 2 of the menus, which makes it possible to make one of the
following choices:
· LING
select the language of the remote time control
· PAR
menu not available
· PARC
menu not available
· >>
Using key K4 (>>), one passes from page 1 to page 2 and vice versa.
Return to the operating mode takes place automatically, after 2 minutes, or manually using the KM key for about
10 seconds
.
6.1 - Displaying the system parameters
Pressing down key KM for about 10 seconds and then using key K1 (INFO), the menu for the display of the
operating parameters of the remote time control is selected.
Using keys K1 (<<) and K4 (>>), it is possible to display the information listed below:
· TMP ESTERNA
external temperature
· PRESSIONE
data not available
· TMP MANDATA
boiler temperature
· BRUCIATORE
data not available
· TMP SAN
domestic hot water temperature (only with water heater)
· PORTATA SAN
data not available
· STATO SAN
domestic hot water mode status (0 inactive, 1 active)
· TMP RITORNO
data not available
· TMP AMBIENT
room temperature
· REG AMBIENT
room temperature requested
· TEMP CALC
supply temperature calculated
· CODICE ID
identification number of the remote control version
· VERSIONE
number of the version of the remote control’s firmware
Return to the operating mode takes place automatically, after 2 minutes, or manually using the KM key for about
10 seconds
.
Possible values adopted by the afore-mentioned variables: