18
3.23.1 - Rotation
of the flue
discharge/air
intake fittings
The connection of the flue pipes to
the heater can be rotated through
360°, in increments of 90°. This
makes it possible to choose
between 4 different relative
positions (see figure 10) of the
discharge and intake pipes,
allowing for great versatility of
installation.
To carry out this operation (refer to
figure 10):
remove the fixing screws “A”
from the top cover “B”.
rotate the top cover to the
desired position.
reinsert the fixing screws “A” and
lock them down without
excessive force.
Note:
“C” indicates the front of the
heater in the top views.
In any position of rotation of the
cover, the intake and discharge
fittings can be rotated on
themselves, allowing for optimal
positioning of the connections for
the combustion analysis and/or for
the condensation discharge.
3 - INSTALLATION
Figure 10 - Possibility of rotating the discharge and intake