20
21
18
3. Connect the neutral (white) wire
c
and the ground (green or bare) wire
d
(of
the range cable) using a UL listed wire connector.
4. Connect the 2 red wires
g
together using a UL listed wire connector.
5. Install junction box cover.
Connect to the Range
IMPORTANT: Use this method only if local codes permit connecting chassis
ground conductor to neutral wire of power supply cord.
1. Feed the electric cable wires through the flexible metal conduit.
NOTE: Allow enough slack to easily attach the wires to the terminal block.
2. Remove the access panel located on the bottom right-hand side of the
back panel to uncover the electrical terminal block.
b
a
c
a
Electrical Access Panel
b
Conduit Opening
c
Recessed Area
3. Install a UL listed strain relief (not provided) to the conduit opening in
the bracket, and then completely tighten the strain relief nut.
4. Thread the end of the conduit through the strain relief.
NOTE: Allow enough slack to connect the wires to the terminal
block.
b
c
a
a
Jumper Wire
b
UL Listed Strain Relief
c
Conduit
Installation Instructions
19
5. Using a 5/16" nut driver and one of the l0-32 hex nuts, connect the ground
(green or bare) wire from the flexible metal conduit to the center terminal
block post along with the green jumper wire from the range.
6. Using 10-32 hex nuts, connect the red and black wires from the power cord
to the outer posts of the terminal block with the corresponding red and
black wires from the range.
7. Tighten the hex nuts completely, and then verify the connection.
8. Position the lower part of the strain relief under the flexible metal conduit
and tighten the strain relief screws.
NOTE: Before tightening, make sure the strain relief is positioned over
the flexible metal conduit and NOT the wires.
9. Replace the electrical access panel.
10. Tuck excess conduit into the recessed area of the back panel.
4-WIRE CONNECTION (UNGROUNDED NEUTRAL)
Connect to the House Electrical Supply - U.S.A. Only
IMPORTANT: Use the 4-wire cable from home power supply in the U.S. where
local codes do not allow grounding through neutral, new branch circuit
installations (l99e NEC), mobile homes and recreational vehicles, new
construction and in Canada.
Ungrounded Neutral
i
b
c
d
g
f
e
h
a
a
Junction Box
b
Black Wires
c
Red Wires
d
Cable from Range
e
UL listed or CSA
Approved Conduit
Connector
f
Ground (Green or
Bare) Wires
g
UL Listed Wire
Connector
h
Neutral (White) Wires
i
House Electrical Supply
1. Connect the 2 black wires
b
together using a UL listed wire connector.
2. Connect the 2 red wires
c
together using a UL listed wire connector.
3. Connect the 2 neutral (white) wires
h
together using a UL listed wire connector.
4. Connect the ground (green or bare) wire
f
from the range cable to the ground
(green or bare) wire (in the junction box) using a UL listed wire connector.
5. Install junction box cover.
Installation Instructions