WARNING

 

Electrical Shock Hazard

16

DIRECT WIRE - U.S.A. ONLY

Disconnect power before servicing.
Improper connection of aluminum house wiring and copper 

appliance leads can result in an electrical hazard or fire. If the home 

has aluminum wiring, only use connectors designed and UL listed 

for joining copper to aluminum and precisely follow the 

manufacturer's recommended procedure. Aluminum-to-Copper 

connections must conform with local codes.
Use 8 gauge copper or 6 gauge aluminum wire.
Electrically ground range.
Failure to do so can result in death, fire or electrical shock.

Be sure your appliance is properly installed and grounded by a qualified 

technician. Ask your dealer to recommend a qualified technician or an 

authorized repair service.

A circuit breaker is recommended.

The range can be connected directly to the circuit breaker box (or fused

disconnect) through flexible or nonmetallic sheathed, copper or aluminum

cable.

Allow at least 6 ft (1.8 m) of slack in the line so that the range can be

moved if servicing is ever necessary.

A UL listed conduit connector must be provided at each end of the power

supply cable (at the range and at the junction box).

Wire sizes and connections must conform with the rating of the range.

The tech sheet and wiring diagram are included with the range.

This appliance is manufactured with the chassis connected to the neutral by a 

green ground jumper wire. After making sure that the power has been turned 

off, connect the flexible conduit from the oven to the junction box using a UL 

listed conduit connector. The Grounded Neutral and Ungrounded Neutral 

Graphics on the following pages and the instructions provided, present the 

most common way of connecting the ovens. Your local codes and ordinances, 

of course, take precedence over these instructions. Complete electrical 

connections according to local codes and ordinances. 

Installation Instructions

WARNING

 

Electrical Shock Hazard

17

3-WIRE CONNECTION (GROUNDED NEUTRAL) 

Grounding through the neutral conductor is prohibited for new 

branch-circuit installations (1996 NEC); mobile homes; and 

recreational vehicles, or in an area where local codes prohibit 

grounding through the neutral conductor. For installations where 

grounding through the neutral conductor is prohibited, see the 

Ungrounded Neutral graphic. 

Use grounding terminal or lead to ground unit. 
Connect neutral terminal or lead to branch circuit neutral in 

usual manner. 
Failure to do so could result in death, fire or electric shock.

Connect to the House Electrical Supply
IMPORTANT: Use the 3-wire cable from home power supply where local 
codes permit a 3-wire connection.
1.  Disconnect power.

Grounded Neutral

a

b

c

d

g

h

f

e

i

Junction Box

 

Black Wires 

Neutral (White)

 

Wire

Ground (Green or

 

Bare) Wire

Cable from Range

UL Listed Conduit

 

Connector 

Red Wires

UL Listed Wire Connectors

 

House Electrical Supply

2. 

Connect the 2 black wires

 

b

 

together using a UL listed wire connector.

Installation Instructions

Summary of Contents for 2126809

Page 1: ...PORTANTE DE 30 PO COS 305AERC INSTRUCTIONS D INSTALLATION INSPIRING THE WORLD S KITCHEN IMPORTANT SAFETY INSTRUCTIONS Carefully read the following Important information redarding installation safety a...

Page 2: ...e for your products We hope that this manual will help you learn to use the product in the safest and most effective manner If you have any questions or concerns please contact the dealer from whom yo...

Page 3: ...or serious bodily injury A potentially hazardous situation which if not avoided may result in moderate or minor injury All safety messages will tell you what the potential hazard is tell you how to re...

Page 4: ...ler Installation Requirements 5 LOCATION REQUIREMENTS VENTILATION IMPORTANT Observe all governing codes and ordinances It is the installer s responsibility to comply with installation clearances if sp...

Page 5: ...rated at 250 volts 50 amps and intended for use with ranges The ground must be revised so the green ground wire of the 4 wire power supply is connected to the chassis See 4 Wire Connection Power Supp...

Page 6: ...r cord The range can be fitted with a 3 or 4 wire NEMA 14 50 or 10 50 type SRDT or ST as required power cord rated at 250 volt AC minimum 50 amp with 3 open end spade lug connectors with upturned ends...

Page 7: ...ack up onto the cardboard or hardboard Installation Instructions WARNING Tip Over Hazard 11 STEP 2 INSTALL ANTI TIP BRACKET A child or adult can tip the range and be killed Connect anti tip bracket to...

Page 8: ...ead the end of the power cord through the strain relief NOTE Allow enough slack to connect the wires to the terminal block c a UL Listed Strain Relief a b Power Cord b c Jumper Wire 5 Using a 5 16 nut...

Page 9: ...crew back onto its end that is fastened to the center post on the terminal block 7 Use 5 16 nut driver to connect the neutral white wire to the center terminal block post with one of the 10 32 hex nut...

Page 10: ...und jumper wire After making sure that the power has been turned off connect the flexible conduit from the oven to the junction box using a UL listed conduit connector The Grounded Neutral and Ungroun...

Page 11: ...res from the power cord to the outer posts of the terminal block with the corresponding red and black wires from the range 7 Tighten the hex nuts completely and then verify the connection 8 Position t...

Page 12: ...nto final location making sure rear leveling leg slides into anti tip bracket Leave a l 2 e cm gap between the back of the range and the back wall 2 Place the outside of your foot against the bottom f...

Page 13: ...nto a grounded outlet Electrical supply is connected Contact a qualified electrician to verify the electrical supply Installation Instructions STEP 5 COMPLETE INSTALLATION 1 2 2a 1a P2 P1 SCER S2 2 4...

Page 14: ...urit suivront le symbole d alerte de s curit et le mot DANGER AVERTISSEMENT ou ATTENTION Ces mots signifient Une situation de danger imminent Vous courez le risque d un d c s ou de blessures graves si...

Page 15: ...ntes a Vis de 16 x 1 5 8 2 b La bride antibasculement REMARQUE Les brides antibasculement doivent tre solidement fix es au sous plancher La profondeur du plancher peut n cessiter des vis plus longues...

Page 16: ...cm RENSEIGNEMENTS G N RAUX La cuisini re doit tre plac e de mani re permettre une utilisation pratique dans la cuisine Dans le cas d une cuisini re encastr e l enceinte doit recouvrir compl tement les...

Page 17: ...n d installer correctement votre cuisini re vous devez d terminer le type de connexion lectrique que vous allez utiliser et suivre les instructions indiqu es ici La cuisini re doit tre connect e la te...

Page 18: ...tion conducteurs en cuivre et inversement Le raccordement correct est un cordon conducteurs en cuivre et une prise secteur conducteurs en cuivre La prise secteur doit tre situ e de telle sorte que le...

Page 19: ...de fibres dur au sol devant la cuisini re pour prot ger le plancher deux personnes au moins redresser la cuisini re et la placer sur le carton ou le panneau de fibres dur Instructions d installation...

Page 20: ...d voiler le bornier Instructions d installation 36 a b c a Panneau d acc s au raccordement l alimentation lectrique b Ouverture du cordon d alimentation c Encastrement 3 Installer un serre c ble homol...

Page 21: ...rer le cavalier vert de sous la vis de terre et le remplacer par le conducteur vert du cordon d alimentation et serrer la vis de terre 6 Former une boucle avec le cavalier vert retir de la vis de terr...

Page 22: ...t correctement install e et reli e la terre par un technicien qualifi Demandez votre revendeur de vous recommander un technicien qualifi ou un centre de service de r paration agr L emploi d un disjonc...

Page 23: ...ges h Connecteurs de fils homologation UL i Alimentation lectrique du domicile Instructions d installation AVERTISSEMENT Risque de choc lectrique 42 2 Connecter ensemble les 2 conducteurs noirs bavec...

Page 24: ...IMPORTANT Utiliser le c ble 4 conducteurs provenant de l alimentation lectrique du domicile aux tats Unis lorsque les codes locaux ne permettent pas la mise la terre par l interm diaire du conducteur...

Page 25: ...valier vert retir de la vis de terre sur son extr mit attach e la borne centrale du bornier 7 l aide d un tourne crou de 5 16 raccorder le conducteur neutre blanc sur la borne centrale du bornier au m...

Page 26: ...se of material resources IMPORTANT Do Not Return This Product To The Store If you have a problem with this product please contact Cosmo Customer Support at 1 888 784 3108 DATED PROOF OF PURCHASE MODEL...

Page 27: ...n of this manual is available at www cosmoappliances com Cosmo is constantly making efforts to improve the quality and performance of our products so we may make changes to our appliances without upda...

Reviews: